| Specification | GW10K-MS-CN-G40GoodWe Technologies Co., Ltd. · ChinaDeep comparison fields reviewed | GW10K-MS-30GoodWe Technologies Co., Ltd. · AustraliaDeep comparison fields reviewed |
|---|---|---|
| AC output | ||
| Rated AC active power | 10000 Wrated output power; exact source raw value '10000' W. Converted exactly to website base unit; W and VA not interchanged. Source unit W Official source ↗ China MS G4 technical sheet exact-model column Revision GoodWe MS G4 China technical sheet; revision/date not printed in document (official file independently reopened 2026-10-02) · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 10000 Wnominal output power; exact source raw value '10000' W. Converted exactly to website base unit; W and VA not interchanged. Source unit W Official source ↗ User Manual V2.4 technical parameters pp.51-56 exact-model column Revision V2.4 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Maximum AC apparent output | 11000 VAmaximum apparent output power; exact source raw value '11000' VA. Converted exactly to website base unit; W and VA not interchanged. Source unit VA Official source ↗ China MS G4 technical sheet exact-model column Revision GoodWe MS G4 China technical sheet; revision/date not printed in document (official file independently reopened 2026-10-02) · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 10000 VAmax AC apparent power; exact source raw value '10000' VA. Converted exactly to website base unit; W and VA not interchanged. Source unit VA Official source ↗ User Manual V2.4 technical parameters pp.51-56 exact-model column Revision V2.4 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Connection phases | 1Connection phase count bound to Task10 exact identity (single-phase); nominal wiring/voltage evidence retained. Official source ↗ China MS G4 technical sheet exact-model column Revision GoodWe MS G4 China technical sheet; revision/date not printed in document (official file independently reopened 2026-10-02) · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 1Connection phase count bound to Task10 exact identity (single-phase); nominal wiring/voltage evidence retained. Official source ↗ User Manual V2.4 technical parameters pp.51-56 exact-model column Revision V2.4 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| PV input & tracking | ||
| Independent MPPT trackers | 2MPP tracker count; exact model/market Task10 evidence reused. Official source ↗ China MS G4 technical sheet exact-model column Revision GoodWe MS G4 China technical sheet; revision/date not printed in document (official file independently reopened 2026-10-02) · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 3MPP tracker count; exact model/market Task10 evidence reused. Official source ↗ User Manual V2.4 technical parameters pp.51-56 exact-model column Revision V2.4 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| MPPT operating window minimum | 40 VMPPT operating range; endpoint of exact official range [40, 560], not the absolute DC limit. Source unit V Official source ↗ China MS G4 technical sheet exact-model column Revision GoodWe MS G4 China technical sheet; revision/date not printed in document (official file independently reopened 2026-10-02) · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 40 VMPPT operating range; endpoint of exact official range [40, 560], not the absolute DC limit. Source unit V Official source ↗ User Manual V2.4 technical parameters pp.51-56 exact-model column Revision V2.4 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| MPPT operating window maximum | 560 VMPPT operating range; endpoint of exact official range [40, 560], not the absolute DC limit. Source unit V Official source ↗ China MS G4 technical sheet exact-model column Revision GoodWe MS G4 China technical sheet; revision/date not printed in document (official file independently reopened 2026-10-02) · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 560 VMPPT operating range; endpoint of exact official range [40, 560], not the absolute DC limit. Source unit V Official source ↗ User Manual V2.4 technical parameters pp.51-56 exact-model column Revision V2.4 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| DC operating voltage minimum | Unknown | Unknown |
| DC operating voltage maximum | Unknown | Unknown |
| Maximum PV input voltage | 600 Vmax input voltage; exact model/market Task10 evidence reused. Source unit V Official source ↗ China MS G4 technical sheet exact-model column Revision GoodWe MS G4 China technical sheet; revision/date not printed in document (official file independently reopened 2026-10-02) · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 600 Vmax input voltage; exact model/market Task10 evidence reused. Source unit V Official source ↗ User Manual V2.4 technical parameters pp.51-56 exact-model column Revision V2.4 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Maximum input current per tracker/input | 20 Aper MPPT; per-MPPT/input maximum, not total inverter current. Source unit A Official source ↗ China MS G4 technical sheet exact-model column Revision GoodWe MS G4 China technical sheet; revision/date not printed in document (official file independently reopened 2026-10-02) · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 20 Aper MPPT; per-MPPT/input maximum, not total inverter current. Source unit A Official source ↗ User Manual V2.4 technical parameters pp.51-56 exact-model column Revision V2.4 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Maximum PV short-circuit current | 26 Aper MPPT; per-MPPT/input maximum, not total inverter current. Source unit A Official source ↗ China MS G4 technical sheet exact-model column Revision GoodWe MS G4 China technical sheet; revision/date not printed in document (official file independently reopened 2026-10-02) · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 25 Aper MPPT; per-MPPT/input maximum, not total inverter current. Source unit A Official source ↗ User Manual V2.4 technical parameters pp.51-56 exact-model column Revision V2.4 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Efficiency & environment | ||
| Maximum conversion efficiency | 98.1 %maximum efficiency; exact model/market Task10 evidence reused. Source unit % Official source ↗ China MS G4 technical sheet exact-model column Revision GoodWe MS G4 China technical sheet; revision/date not printed in document (official file independently reopened 2026-10-02) · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 97.9 %maximum efficiency; exact model/market Task10 evidence reused. Source unit % Official source ↗ User Manual V2.4 technical parameters pp.51-56 exact-model column Revision V2.4 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| European efficiency | Unknown | 97.3 %European efficiency; exact model/market Task10 evidence reused. Source unit % Official source ↗ User Manual V2.4 technical parameters pp.51-56 exact-model column Revision V2.4 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Operating ambient temperature minimum | -25 °Coperating range; lower endpoint of exact official range [-25, 60]. Source unit °C Official source ↗ China MS G4 technical sheet exact-model column Revision GoodWe MS G4 China technical sheet; revision/date not printed in document (official file independently reopened 2026-10-02) · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | -25 °Coperating range; lower endpoint of exact official range [-25, 60]. Source unit °C Official source ↗ User Manual V2.4 technical parameters pp.51-56 exact-model column Revision V2.4 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Operating ambient temperature maximum | 60 °Coperating range; upper endpoint of exact official range [-25, 60]. Source unit °C Official source ↗ China MS G4 technical sheet exact-model column Revision GoodWe MS G4 China technical sheet; revision/date not printed in document (official file independently reopened 2026-10-02) · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 60 °Coperating range; upper endpoint of exact official range [-25, 60]. Source unit °C Official source ↗ User Manual V2.4 technical parameters pp.51-56 exact-model column Revision V2.4 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Enclosure protection | IP66Official exact-model enclosure ingress-protection rating; no environmental design approval implied. Official source ↗ China MS G4 technical sheet exact-model column Revision GoodWe MS G4 China technical sheet; revision/date not printed in document (official file independently reopened 2026-10-02) · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | IP66Official enclosure ingress-protection rating; catalogue description only, not a safety or suitability approval. Official source ↗ Official technical data / Ingress Protection Rating; exact family/model applicability for GW10K-MS-30. Revision User Manual V2.4-2026-09-10 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Surge protection | DC: Type II; AC: Type IIOfficial surge-protection configuration for this exact model family; optional enhancements are preserved verbatim where stated. Official source ↗ China MS G4 sheet: DC surge protection = 二级 (Type II); AC surge protection = 二级 (Type II). Revision GoodWe MS G4 China technical sheet; revision/date not printed in document (official file independently reopened 2026-10-02) · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | DC SPD and AC SPD shown in official circuit diagram; SPD type/class not stated in reviewed locatorOfficial surge-protection configuration for this exact model family; optional enhancements are preserved verbatim where stated. Official source ↗ Official Protection table / surge-protection rows for family containing exact model GW10K-MS-30. Revision User Manual V2.4-2026-09-10 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Warranty | ||
| Warranty and eligibility | Unknown | Unknown |