Compare inverters.
Exact market specifications side by side, limited to one reviewed comparison category.
Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.
Hybrid / smart energy inverter
2 exact records
Edit selection
| Specification | SUN-7.6K-SG05LP1-EU-SM2-PNingbo Deye Inverter Technology Co., Ltd. · Global / Europe (EU-labelled)Deep comparison fields reviewed | WIT 5K-XHUGrowatt New Energy · Global / ROWDeep comparison fields reviewed |
|---|---|---|
| AC output | ||
| Rated AC active power | 7600 Wrated AC input/output active power Official source ↗ | 5000 WInput/Output AC, AC input/output nominal power (Grid); grid output is second value after slash Official source ↗ |
| Maximum AC apparent output | 8360 VAmaximum AC input/output apparent power Official source ↗ | 5500 VAInput/Output AC, Max. AC input/output apparent power (Grid); grid output is second value after slash Official source ↗ |
| Connection phases | 1Official current product family identifies exact model as single-phase. Official source ↗ | 3Input/Output AC, AC grid connection type 3P3W+PE / 3P4W+PE Official source ↗ |
| PV input & tracking | ||
| Independent MPPT trackers | 2MPP trackers Official source ↗ | 1Input data(PV), No. of MPP trackers Official source ↗ |
| MPPT operating window minimum | 150 VMPPT operating range Official source ↗ | 150 VInput data(PV), MPPT working voltage range Official source ↗ |
| MPPT operating window maximum | 425 VMPPT operating range Official source ↗ | 850 VInput data(PV), MPPT working voltage range Official source ↗ |
| DC operating voltage minimum | Unknown | Unknown |
| DC operating voltage maximum | Unknown | Unknown |
| Maximum PV input voltage | 500 Vmaximum PV input voltage Official source ↗ | 1000 VInput data(PV), Max. input voltage Official source ↗ |
| Maximum input current per tracker/input | 32 / 32 Aper-MPPT operating PV input current Official source ↗ | 40 AInput data(PV), Max. input current per MPP tracker; tracker-specific vector preserved where printed Official source ↗ |
| Maximum PV short-circuit current | 48 / 48 Aper-MPPT short-circuit current Official source ↗ | 50 AInput data(PV), Max. short-circuit current per MPP tracker; tracker-specific vector preserved where printed Official source ↗ |
| Efficiency & environment | ||
| Maximum conversion efficiency | 97.6 %maximum efficiency Official source ↗ | 98.1 %Efficiency, Max. efficiency Official source ↗ |
| European efficiency | 96.5 %Euro efficiency Official source ↗ | 97.2 %Efficiency, European efficiency Official source ↗ |
| Operating ambient temperature minimum | -40 °Coperating temperature and derating threshold; derating above 45 °C Official source ↗ | -30 °CGeneral, Operating temperature range minimum Official source ↗ |
| Operating ambient temperature maximum | 60 °Coperating temperature and derating threshold; derating above 45 °C Official source ↗ | 60 °CGeneral, Operating temperature range maximum; derating >45°C noted in source Official source ↗ |
| Enclosure protection | IP65Official current product page enclosure rating. Official source ↗ | IP66General, IP degree Official source ↗ |
| Surge protection | Type II (DC), Type II (AC)Official current product page surge-protection level. Official source ↗ | Unknown |
| Warranty | ||
| Warranty and eligibility | 5 years / up to 10 years*Official current product page; extension availability is country/region dependent and subject to manufacturer policy. Official source ↗ | Unknown |