PUBLIC CATALOGUE • 632 comparison-ready inverter records. Incomplete identities are not shown.
← Choose inverters

Compare inverters.

Exact market specifications side by side, limited to one reviewed comparison category.

Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.

Hybrid / smart energy inverter 2 exact records
Edit selection
Inverter electrical comparison
SpecificationGW100K07-ETCGoodWe Technologies Co., Ltd. · Global catalog (Australia/Germany grid-range settings separated as material variants)Deep comparison fields reviewedMIN 3000TL-XH2Growatt New Energy · Global / ROWDeep comparison fields reviewed
AC output
Rated AC active power100000 WOn-grid nominal output power; exact source raw value '100 kW' kW. Converted exactly to website base unit; W and VA not interchanged.
Official source ↗
3000 Wrated AC output active power
Official source ↗
Maximum AC apparent output110000 VAMax apparent power to utility grid; exact source raw value '110 kVA' kVA. Converted exactly to website base unit; W and VA not interchanged.
Official source ↗
3000 VAmaximum AC apparent power
Official source ↗
Connection phases3Connection phase count bound to Task10 exact identity (three-phase); nominal wiring/voltage evidence retained.
Official source ↗
single_phaseExact model/market phase classification retained from Task10 source-worker review; no cross-model interpolation.
Official source ↗
PV input & tracking
Independent MPPT trackers2MPP trackers; exact model/market Task10 evidence reused.
Official source ↗
2independent MPP trackers
Official source ↗
MPPT operating window minimum250 VMPPT operating range; endpoint of exact official range [250, 960], not the absolute DC limit.
Official source ↗
40 VMPPT operating voltage range
Official source ↗
MPPT operating window maximum960 VMPPT operating range; endpoint of exact official range [250, 960], not the absolute DC limit.
Official source ↗
490 VMPPT operating voltage range
Official source ↗
DC operating voltage minimumUnknownUnknown
DC operating voltage maximumUnknownUnknown
Maximum PV input voltage1000 VPV max input voltage; exact model/market Task10 evidence reused.
Official source ↗
500 VPV maximum input voltage
Official source ↗
Maximum input current per tracker/input100 AMax input current per MPPT; per-MPPT/input maximum, not total inverter current.
Official source ↗
16 Amaximum PV current per MPPT
Official source ↗
Maximum PV short-circuit current125 AMax short circuit current per MPPT; per-MPPT/input maximum, not total inverter current.
Official source ↗
24 Amaximum PV short-circuit current per MPPT
Official source ↗
Efficiency & environment
Maximum conversion efficiency97.6 %Max efficiency; exact model/market Task10 evidence reused.
Official source ↗
98.2 %maximum efficiency
Official source ↗
European efficiency97.3 %European efficiency; exact model/market Task10 evidence reused.
Official source ↗
Unknown
Operating ambient temperature minimum-20 °COperating temp; >45°C derating; lower endpoint of exact official range [-20, 60].
Official source ↗
-30 °Coperating ambient range
Official source ↗
Operating ambient temperature maximum60 °COperating temp; >45°C derating; upper endpoint of exact official range [-20, 60].
Official source ↗
60 °Coperating ambient range
Official source ↗
Enclosure protectionIP20Official enclosure ingress-protection rating; catalogue description only, not a safety or suitability approval.
Official source ↗
IP66enclosure ingress protection
Official source ↗
Surge protectionDC: Type II (Type I + II optional); AC: Type II (Type I + II optional)Official surge-protection configuration for this exact model family; optional enhancements are preserved verbatim where stated.
Official source ↗
Unknown
Warranty
Warranty and eligibilityUnknown10Manufacturer warranty statement/options as published; eligibility and local terms may vary and are not independently granted by this catalogue review. QC schema normalization: canonical display-field unit is ''; original Task18 unit metadata was 'years'. The value semantics are preserved in the field value/test condition.
Official source ↗