PUBLIC CATALOGUE • 632 comparison-ready inverter records. Incomplete identities are not shown.
← Choose inverters

Compare inverters.

Exact market specifications side by side, limited to one reviewed comparison category.

Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.

String inverter 2 exact records · Differences include rating conditions and scope.
Edit selection
Inverter electrical comparison
SpecificationGW110K-GTGoodWe Technologies Co., Ltd. · AustraliaDeep comparison fields reviewedFronius Primo GEN24 4.6Fronius International GmbH · Europe / ROW current support selectorDeep comparison fields reviewed
AC output
Rated AC active power110000 WNominal output power; exact source raw value '110 kW' kW. Converted exactly to website base unit; W and VA not interchanged.
Source unit W
Official source ↗
Technical Data table
Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

4600 WAC nominal output (P_ac,r)
Source unit W
Official source ↗
Technical Data > Output Data
Revision Unknown · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Maximum AC apparent output110000 VAAustralia max AC apparent power; exact source raw value '110 kVA' kVA. Converted exactly to website base unit; W and VA not interchanged.
Source unit VA
Official source ↗
Footnote *4
Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

4600 VAMax. output power (P_ac max); apparent-power unit preserved
Source unit VA
Official source ↗
Technical Data > Output Data
Revision Unknown · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Connection phases3Connection phase count bound to Task10 exact identity (three-phase); nominal wiring/voltage evidence retained.
Official source ↗
Technical Data table
Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

1Task23 QC-approved exact-model/market manufacturer specification.
Official source ↗
exact model identity; DC voltage/current/MPPT; AC nominal active W; max apparent VA; grid voltage/frequency
Revision Unknown · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

PV input & tracking
Independent MPPT trackers10MPP trackers; exact model/market Task10 evidence reused.
Official source ↗
Technical Data table
Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

2Number of MPP trackers
Official source ↗
Technical Data > Input Data
Revision Unknown · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

MPPT operating window minimum180 VMPPT operating range; endpoint of exact official range [180, 1000], not the absolute DC limit.
Source unit V
Official source ↗
Technical Data table
Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

230 VMPP voltage range
Source unit V
Official source ↗
Technical Data > Input Data
Revision Unknown · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

MPPT operating window maximum1000 VMPPT operating range; endpoint of exact official range [180, 1000], not the absolute DC limit.
Source unit V
Official source ↗
Technical Data table
Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

530 VMPP voltage range
Source unit V
Official source ↗
Technical Data > Input Data
Revision Unknown · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

DC operating voltage minimumUnknown65 VU_dc min - U_dc max
Source unit V
Official source ↗
Technical Data > Input Data
Revision Unknown · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

DC operating voltage maximumUnknown600 VU_dc min - U_dc max
Source unit V
Official source ↗
Technical Data > Input Data
Revision Unknown · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Maximum PV input voltage1100 VMax input voltage; exact model/market Task10 evidence reused.
Source unit V
Official source ↗
Technical Data table
Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

600 VTask23 QC-approved exact-model/market manufacturer specification.
Source unit V
Official source ↗
Technical Data > Input Data
Revision Unknown · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Maximum input current per tracker/input42 AMax input current per MPPT; per-MPPT/input maximum, not total inverter current.
Source unit A
Official source ↗
Technical Data table
Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

MPPT1 22 / MPPT2 12 AMax. input current (I_dc max), manufacturer two-MPPT topology preserved
Source unit A
Official source ↗
Technical Data > Input Data
Revision Unknown · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Maximum PV short-circuit current52.5 AMax short circuit current per MPPT; per-MPPT/input maximum, not total inverter current.
Source unit A
Official source ↗
Technical Data table
Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

MPPT1 41.25 / MPPT2 22 AMax. short circuit current, module array; exact two-MPPT scope
Source unit A
Official source ↗
Technical Data > Input Data
Revision Unknown · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Efficiency & environment
Maximum conversion efficiency98.8 %Max efficiency; exact model/market Task10 evidence reused.
Source unit %
Official source ↗
Technical Data table
Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

97.6 %Max. efficiency (PV-grid)
Source unit %
Official source ↗
Technical Data > Efficiency
Revision Unknown · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

European efficiency98.4 %European efficiency; exact model/market Task10 evidence reused.
Source unit %
Official source ↗
Technical Data table
Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Unknown
Operating ambient temperature minimum-30 °COperating temp; lower endpoint of exact official range [-30, 60].
Source unit °C
Official source ↗
Technical Data table
Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

-40 °CAmbient temperature range; no extra derating curve inferred
Source unit °C
Official source ↗
Technical Data > General Data
Revision Unknown · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Operating ambient temperature maximum60 °COperating temp; upper endpoint of exact official range [-30, 60].
Source unit °C
Official source ↗
Technical Data table
Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

60 °CAmbient temperature range; no extra derating curve inferred
Source unit °C
Official source ↗
Technical Data > General Data
Revision Unknown · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Enclosure protectionIP66Official enclosure ingress-protection rating; catalogue description only, not a safety or suitability approval.
Official source ↗
Official technical data / Ingress Protection Rating; exact family/model applicability for GW110K-GT.
Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

IP66Degree of protection
Official source ↗
Technical Data > General Data
Revision Unknown · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Surge protectionDC: Type II (Type I + II optional where stated); AC: Type IIOfficial surge-protection configuration for this exact model family; optional enhancements are preserved verbatim where stated.
Official source ↗
Official Protection table / surge-protection rows for family containing exact model GW110K-GT.
Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Unknown
Warranty
Warranty and eligibilityUnknownUnknown