Compare inverters.
Exact market specifications side by side, limited to one reviewed comparison category.
Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.
Hybrid / smart energy inverter
3 exact records
Edit selection
| Specification | X1-HYB-5.0-LVSolaX Power · Global / ROWDeep comparison fields reviewed | MIN 4600TL-XH2Growatt New Energy · Global / ROWDeep comparison fields reviewed | H3-6.0-SmartFox ESS · Global / ROW official siteDeep comparison fields reviewed |
|---|---|---|---|
| AC output | |||
| Rated AC active power | 5000 WManufacturer-published exact-model value; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Official source ↗ | 4600 Wrated AC output active power Official source ↗ | 6000 Wnominal active AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| Maximum AC apparent output | 5000 VAexact model column, manufacturer datasheet Official source ↗ | 4600 VAmaximum AC apparent power Official source ↗ | 6600 VAmaximum apparent AC output for stated market; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| Connection phases | 1Connection phase stated by the exact official family/model evidence and Task10 exact identity record; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Official source ↗ | single_phaseExact model/market phase classification retained from Task10 source-worker review; no cross-model interpolation. Official source ↗ | 3Official exact-model/family phase identity: three-phase. For North-American split-phase, the literal split-phase descriptor is retained rather than converted to a false phase count. No grid-approval inference. Official source ↗ |
| PV input & tracking | |||
| Independent MPPT trackers | 2exact model column, manufacturer datasheet Official source ↗ | 2independent MPP trackers Official source ↗ | 3independent MPP trackers; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| MPPT operating window minimum | Unknown | 40 VMPPT operating voltage range Official source ↗ | 120 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| MPPT operating window maximum | Unknown | 540 VMPPT operating voltage range Official source ↗ | 950 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| DC operating voltage minimum | 80 VManufacturer-published exact-model value; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Official source ↗ | Unknown | Unknown |
| DC operating voltage maximum | 520 VManufacturer-published exact-model value; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Official source ↗ | Unknown | Unknown |
| Maximum PV input voltage | 550 VManufacturer-published exact-model value; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Official source ↗ | 550 VPV maximum input voltage Official source ↗ | 1000 Vmaximum DC voltage; scope: PV input; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| Maximum input current per tracker/input | 16 / 16 Aexact model column, manufacturer datasheet Official source ↗ | 16 Amaximum PV current per MPPT Official source ↗ | 20 / 20 / 20 Amaximum current by MPPT; scope: MPPT1/2/3; raw source cell retained: 20/20/20; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| Maximum PV short-circuit current | 20 / 20 Aexact model column, manufacturer datasheet Official source ↗ | 24 Amaximum PV short-circuit current per MPPT Official source ↗ | 25 / 25 / 25 Amaximum short-circuit current by MPPT; scope: MPPT1/2/3; raw source cell retained: 25/25/25; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| Efficiency & environment | |||
| Maximum conversion efficiency | 97.6 %exact model column, manufacturer datasheet Official source ↗ | 98.4 %maximum efficiency Official source ↗ | 97.7 %maximum conversion efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| European efficiency | Unknown | Unknown | 97.2 %European efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| Operating ambient temperature minimum | -25 °Cexact model column, manufacturer datasheet Official source ↗ | -30 °Coperating ambient range Official source ↗ | -25 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| Operating ambient temperature maximum | 60 °Cexact model column, manufacturer datasheet Official source ↗ | 60 °Coperating ambient range Official source ↗ | 60 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| Enclosure protection | IP65exact model column, manufacturer datasheet Official source ↗ | IP66enclosure ingress protection Official source ↗ | IP65ingress protection rating; scope: enclosure; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| Surge protection | Unknown | Unknown | DC Type II / AC Type IIManufacturer protection table; optional qualifiers retained where stated. Decorative/catalogue use only; no safety approval. Official source ↗ |
| Warranty | |||
| Warranty and eligibility | Unknown | 10Manufacturer warranty statement/options as published; eligibility and local terms may vary and are not independently granted by this catalogue review. QC schema normalization: canonical display-field unit is ''; original Task18 unit metadata was 'years'. The value semantics are preserved in the field value/test condition. Official source ↗ | Unknown |