Compare inverters.
Exact market specifications side by side, limited to one reviewed comparison category.
Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.
String inverter
2 exact records
Edit selection
| Specification | GW36K-MTGoodWe Technologies Co., Ltd. · Global catalog (country/grid exceptions separated as material variants)Deep comparison fields reviewed | GW100K-GTGoodWe Technologies Co., Ltd. · ChileDeep comparison fields reviewed |
|---|---|---|
| AC output | ||
| Rated AC active power | 36000 WNominal output power Official source ↗ | 100000 WNominal output power; exact source raw value '100 kW' kW. Converted exactly to website base unit; W and VA not interchanged. Official source ↗ |
| Maximum AC apparent output | 36000 VAMax. AC apparent power Official source ↗ | 100000 VAChile max AC apparent power; exact source raw value '100 kVA' kVA. Converted exactly to website base unit; W and VA not interchanged. Official source ↗ |
| Connection phases | three-phaseConnection phases stated by exact-family official manufacturer source Official source ↗ | 3Connection phase count bound to Task10 exact identity (three-phase); nominal wiring/voltage evidence retained. Official source ↗ |
| PV input & tracking | ||
| Independent MPPT trackers | 3Number of MPP trackers Official source ↗ | 8MPP trackers; exact model/market Task10 evidence reused. Official source ↗ |
| MPPT operating window minimum | 200 VMPPT operating voltage range Official source ↗ | 180 VMPPT operating range; endpoint of exact official range [180, 1000], not the absolute DC limit. Official source ↗ |
| MPPT operating window maximum | 950 VMPPT operating voltage range Official source ↗ | 1000 VMPPT operating range; endpoint of exact official range [180, 1000], not the absolute DC limit. Official source ↗ |
| DC operating voltage minimum | Unknown | Unknown |
| DC operating voltage maximum | Unknown | Unknown |
| Maximum PV input voltage | 1100 VMax. input voltage Official source ↗ | 1100 VMax input voltage; exact model/market Task10 evidence reused. Official source ↗ |
| Maximum input current per tracker/input | 30 AMax. input current per MPPT Official source ↗ | 42 AMax input current per MPPT; per-MPPT/input maximum, not total inverter current. Official source ↗ |
| Maximum PV short-circuit current | 37.5 AMax. short circuit current per MPPT Official source ↗ | 52.5 AMax short circuit current per MPPT; per-MPPT/input maximum, not total inverter current. Official source ↗ |
| Efficiency & environment | ||
| Maximum conversion efficiency | 98.8 %Maximum efficiency Official source ↗ | 98.8 %Max efficiency; exact model/market Task10 evidence reused. Official source ↗ |
| European efficiency | 98.5 %European efficiency Official source ↗ | 98.4 %European efficiency; exact model/market Task10 evidence reused. Official source ↗ |
| Operating ambient temperature minimum | -30 °COperating temperature range Official source ↗ | -30 °COperating temp; lower endpoint of exact official range [-30, 60]. Official source ↗ |
| Operating ambient temperature maximum | 60 °COperating temperature range Official source ↗ | 60 °COperating temp; upper endpoint of exact official range [-30, 60]. Official source ↗ |
| Enclosure protection | IP65Ingress Protection Rating Official source ↗ | IP66Official enclosure ingress-protection rating; catalogue description only, not a safety or suitability approval. Official source ↗ |
| Surge protection | DC Type III (Type II optional); AC Type III (Type II optional)Protection table; regional/model applicability retained Official source ↗ | DC: Type II (Type I + II optional where stated); AC: Type IIOfficial surge-protection configuration for this exact model family; optional enhancements are preserved verbatim where stated. Official source ↗ |
| Warranty | ||
| Warranty and eligibility | Unknown | Unknown |