PUBLIC CATALOGUE • 632 comparison-ready inverter records. Incomplete identities are not shown.
← Choose inverters

Compare inverters.

Exact market specifications side by side, limited to one reviewed comparison category.

Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.

String inverter 2 exact records
Edit selection
Inverter electrical comparison
SpecificationGW36K-MTGoodWe Technologies Co., Ltd. · Global catalog (country/grid exceptions separated as material variants)Deep comparison fields reviewedGW100K-GTGoodWe Technologies Co., Ltd. · ChileDeep comparison fields reviewed
AC output
Rated AC active power36000 WNominal output power
Official source ↗
100000 WNominal output power; exact source raw value '100 kW' kW. Converted exactly to website base unit; W and VA not interchanged.
Official source ↗
Maximum AC apparent output36000 VAMax. AC apparent power
Official source ↗
100000 VAChile max AC apparent power; exact source raw value '100 kVA' kVA. Converted exactly to website base unit; W and VA not interchanged.
Official source ↗
Connection phasesthree-phaseConnection phases stated by exact-family official manufacturer source
Official source ↗
3Connection phase count bound to Task10 exact identity (three-phase); nominal wiring/voltage evidence retained.
Official source ↗
PV input & tracking
Independent MPPT trackers3Number of MPP trackers
Official source ↗
8MPP trackers; exact model/market Task10 evidence reused.
Official source ↗
MPPT operating window minimum200 VMPPT operating voltage range
Official source ↗
180 VMPPT operating range; endpoint of exact official range [180, 1000], not the absolute DC limit.
Official source ↗
MPPT operating window maximum950 VMPPT operating voltage range
Official source ↗
1000 VMPPT operating range; endpoint of exact official range [180, 1000], not the absolute DC limit.
Official source ↗
DC operating voltage minimumUnknownUnknown
DC operating voltage maximumUnknownUnknown
Maximum PV input voltage1100 VMax. input voltage
Official source ↗
1100 VMax input voltage; exact model/market Task10 evidence reused.
Official source ↗
Maximum input current per tracker/input30 AMax. input current per MPPT
Official source ↗
42 AMax input current per MPPT; per-MPPT/input maximum, not total inverter current.
Official source ↗
Maximum PV short-circuit current37.5 AMax. short circuit current per MPPT
Official source ↗
52.5 AMax short circuit current per MPPT; per-MPPT/input maximum, not total inverter current.
Official source ↗
Efficiency & environment
Maximum conversion efficiency98.8 %Maximum efficiency
Official source ↗
98.8 %Max efficiency; exact model/market Task10 evidence reused.
Official source ↗
European efficiency98.5 %European efficiency
Official source ↗
98.4 %European efficiency; exact model/market Task10 evidence reused.
Official source ↗
Operating ambient temperature minimum-30 °COperating temperature range
Official source ↗
-30 °COperating temp; lower endpoint of exact official range [-30, 60].
Official source ↗
Operating ambient temperature maximum60 °COperating temperature range
Official source ↗
60 °COperating temp; upper endpoint of exact official range [-30, 60].
Official source ↗
Enclosure protectionIP65Ingress Protection Rating
Official source ↗
IP66Official enclosure ingress-protection rating; catalogue description only, not a safety or suitability approval.
Official source ↗
Surge protectionDC Type III (Type II optional); AC Type III (Type II optional)Protection table; regional/model applicability retained
Official source ↗
DC: Type II (Type I + II optional where stated); AC: Type IIOfficial surge-protection configuration for this exact model family; optional enhancements are preserved verbatim where stated.
Official source ↗
Warranty
Warranty and eligibilityUnknownUnknown