| Specification | SPE 10000 ESGrowatt New Energy · Global / ROWDeep comparison fields reviewed | GW75K-ETR-L-G10GoodWe Technologies Co., Ltd. · Global catalog (exact country/grid certificate not asserted)Deep comparison fields reviewed | KH10.5Fox ESS · Global / ROW official siteDeep comparison fields reviewed |
|---|---|---|---|
| AC output | |||
| Rated AC active power | 10000 Wrated AC output power Official source ↗ | 75000 WOfficial manufacturer technical-table value for the exact model; no compatibility, grid, design or publication approval implied. Official source ↗ | 10500 WAC OUTPUT rated active power; exact KH model Official source ↗ |
| Maximum AC apparent output | 10000 VArated/maximum AC apparent output basis as published Official source ↗ | 75000 VAOfficial maximum AC apparent output rating for the exact model; W and VA kept separate and model/market footnotes retained. Official source ↗ | 10500 VAmaximum apparent AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| Connection phases | 1Task10 exact-model evidence records phase as 'single-phase'; normalized to 1 connection phase(s). Identity/category source is official Growatt evidence; no grid approval inferred. Official source ↗ | 3Connection phase count from official family/model description and exact identity (three-phase). Official source ↗ | 1Official exact-model/family phase identity: single-phase. For North-American split-phase, the literal split-phase descriptor is retained rather than converted to a false phase count. No grid-approval inference. Official source ↗ |
| PV input & tracking | |||
| Independent MPPT trackers | 2MPP tracker count Official source ↗ | 10Official manufacturer technical-table value for the exact model; no compatibility, grid, design or publication approval implied. Official source ↗ | 4independent MPP trackers; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| MPPT operating window minimum | 60 VMPPT operating voltage range; lower bound of the manufacturer MPPT operating range. Official source ↗ | 160 VEndpoint of the official MPPT operating voltage range for the exact model; not the absolute DC limit. Official source ↗ | 80 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| MPPT operating window maximum | 480 VMPPT operating voltage range; upper bound of the manufacturer MPPT operating range. Official source ↗ | 800 VEndpoint of the official MPPT operating voltage range for the exact model; not the absolute DC limit. Official source ↗ | 500 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| DC operating voltage minimum | Unknown | Unknown | Unknown |
| DC operating voltage maximum | Unknown | Unknown | Unknown |
| Maximum PV input voltage | 550 Vmaximum PV input voltage Official source ↗ | 850 VOfficial manufacturer technical-table value for the exact model; no compatibility, grid, design or publication approval implied. Official source ↗ | 600 Vmaximum DC voltage; scope: PV input; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| Maximum input current per tracker/input | 27 Amaximum PV input current per MPPT Official source ↗ | 42 AOfficial maximum per-MPPT value for the exact model; not summed across trackers. Official source ↗ | 16 / 16 / 16 / 16 Amaximum input current by MPPT; scope: MPPT; raw source cell retained: 16/16/16/16; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| Maximum PV short-circuit current | 34 Amaximum PV short-circuit current per MPPT Official source ↗ | 55 AOfficial maximum per-MPPT value for the exact model; not summed across trackers. Official source ↗ | 20 / 20 / 20 / 20 Amaximum short-circuit current by MPPT; scope: MPPT; raw source cell retained: 20/20/20/20; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| Efficiency & environment | |||
| Maximum conversion efficiency | 96.5 %maximum efficiency Official source ↗ | 97.4 %Official manufacturer technical-table value for the exact model; no compatibility, grid, design or publication approval implied. Official source ↗ | 97.8 %maximum conversion efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| European efficiency | Unknown | 96.8 %Official manufacturer technical-table value for the exact model; no compatibility, grid, design or publication approval implied. Official source ↗ | 97.4 %European efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| Operating ambient temperature minimum | -10 °Coperating ambient range; lower ambient operating-temperature bound. Official source ↗ | -35 °COfficial manufacturer technical-table value for the exact model; no compatibility, grid, design or publication approval implied. Official source ↗ | -25 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| Operating ambient temperature maximum | 50 °Coperating ambient range; upper ambient operating-temperature bound. Official source ↗ | 60 °COfficial manufacturer technical-table value for the exact model; no compatibility, grid, design or publication approval implied. Official source ↗ | 60 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| Enclosure protection | IP20enclosure ingress protection Official source ↗ | IP66Official enclosure ingress-protection rating; catalogue description only, not a safety or suitability approval. Official source ↗ | IP65ingress protection rating; scope: enclosure; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| Surge protection | Unknown | DC: Type II (Type I + II optional); AC: Type IIOfficial surge-protection configuration for this exact model family; optional enhancements are preserved verbatim where stated. Official source ↗ | DC Type II / AC Type IIManufacturer protection table; optional qualifiers retained where stated. Decorative/catalogue use only; no safety approval. Official source ↗ |
| Warranty | |||
| Warranty and eligibility | Unknown | Unknown | Unknown |