PUBLIC CATALOGUE • 632 comparison-ready inverter records. Incomplete identities are not shown.
← Choose inverters

Compare inverters.

Exact market specifications side by side, limited to one reviewed comparison category.

Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.

Hybrid / smart energy inverter 3 exact records
Edit selection
Inverter electrical comparison
SpecificationSPE 10000 ESGrowatt New Energy · Global / ROWDeep comparison fields reviewedGW75K-ETR-L-G10GoodWe Technologies Co., Ltd. · Global catalog (exact country/grid certificate not asserted)Deep comparison fields reviewedH1-5.0-E-G2-WLFox ESS · Global / ROW official site — exact hybrid modelDeep comparison fields reviewed
AC output
Rated AC active power10000 Wrated AC output power
Official source ↗
75000 WOfficial manufacturer technical-table value for the exact model; no compatibility, grid, design or publication approval implied.
Official source ↗
5000 Wrated active AC output; scope: grid AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Maximum AC apparent output10000 VArated/maximum AC apparent output basis as published
Official source ↗
75000 VAOfficial maximum AC apparent output rating for the exact model; W and VA kept separate and model/market footnotes retained.
Official source ↗
5500 VAmaximum apparent AC output for stated market/grid variant; scope: grid AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Connection phases1Task10 exact-model evidence records phase as 'single-phase'; normalized to 1 connection phase(s). Identity/category source is official Growatt evidence; no grid approval inferred.
Official source ↗
3Connection phase count from official family/model description and exact identity (three-phase).
Official source ↗
1Official exact-model/family phase identity: single-phase. For North-American split-phase, the literal split-phase descriptor is retained rather than converted to a false phase count. No grid-approval inference.
Official source ↗
PV input & tracking
Independent MPPT trackers2MPP tracker count
Official source ↗
10Official manufacturer technical-table value for the exact model; no compatibility, grid, design or publication approval implied.
Official source ↗
2independent MPP trackers; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
MPPT operating window minimum60 VMPPT operating voltage range; lower bound of the manufacturer MPPT operating range.
Official source ↗
160 VEndpoint of the official MPPT operating voltage range for the exact model; not the absolute DC limit.
Official source ↗
80 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
MPPT operating window maximum480 VMPPT operating voltage range; upper bound of the manufacturer MPPT operating range.
Official source ↗
800 VEndpoint of the official MPPT operating voltage range for the exact model; not the absolute DC limit.
Official source ↗
550 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
DC operating voltage minimumUnknownUnknownUnknown
DC operating voltage maximumUnknownUnknownUnknown
Maximum PV input voltage550 Vmaximum PV input voltage
Official source ↗
850 VOfficial manufacturer technical-table value for the exact model; no compatibility, grid, design or publication approval implied.
Official source ↗
600 Vmaximum DC voltage; scope: PV input; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Maximum input current per tracker/input27 Amaximum PV input current per MPPT
Official source ↗
42 AOfficial maximum per-MPPT value for the exact model; not summed across trackers.
Official source ↗
16 / 16 Amaximum input current by tracker; scope: MPPT1/MPPT2; raw source cell retained: 16/16; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Maximum PV short-circuit current34 Amaximum PV short-circuit current per MPPT
Official source ↗
55 AOfficial maximum per-MPPT value for the exact model; not summed across trackers.
Official source ↗
20 / 20 Amaximum short-circuit current by tracker; scope: MPPT1/MPPT2; raw source cell retained: 20/20; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Efficiency & environment
Maximum conversion efficiency96.5 %maximum efficiency
Official source ↗
97.4 %Official manufacturer technical-table value for the exact model; no compatibility, grid, design or publication approval implied.
Official source ↗
97.08 %maximum conversion efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
European efficiencyUnknown96.8 %Official manufacturer technical-table value for the exact model; no compatibility, grid, design or publication approval implied.
Official source ↗
96.3 %European efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Operating ambient temperature minimum-10 °Coperating ambient range; lower ambient operating-temperature bound.
Official source ↗
-35 °COfficial manufacturer technical-table value for the exact model; no compatibility, grid, design or publication approval implied.
Official source ↗
-25 °Cambient operating range; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Operating ambient temperature maximum50 °Coperating ambient range; upper ambient operating-temperature bound.
Official source ↗
60 °COfficial manufacturer technical-table value for the exact model; no compatibility, grid, design or publication approval implied.
Official source ↗
60 °Cambient operating range; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Enclosure protectionIP20enclosure ingress protection
Official source ↗
IP66Official enclosure ingress-protection rating; catalogue description only, not a safety or suitability approval.
Official source ↗
IP65ingress protection rating; scope: enclosure; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Surge protectionUnknownDC: Type II (Type I + II optional); AC: Type IIOfficial surge-protection configuration for this exact model family; optional enhancements are preserved verbatim where stated.
Official source ↗
DC Type II / AC Type IIIManufacturer protection table; optional qualifiers retained where stated. Decorative/catalogue use only; no safety approval.
Official source ↗
Warranty
Warranty and eligibilityUnknownUnknownUnknown