Compare inverters.
Exact market specifications side by side, limited to one reviewed comparison category.
Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.
String inverter
2 exact records
Edit selection
| Specification | Fronius Symo GEN24 5.0Fronius International GmbH · Europe / ROWDeep comparison fields reviewed | GW2500-XS-30GoodWe Technologies Co., Ltd. · Global / current international catalogDeep comparison fields reviewed |
|---|---|---|
| AC output | ||
| Rated AC active power | 5000 W Official source ↗ | 2500 Wnominal output active power; exact source raw value '2500' W. Converted exactly to website base unit; W and VA not interchanged. Official source ↗ |
| Maximum AC apparent output | 5000 VA Official source ↗ | 2500 VAmaximum AC apparent power; exact source raw value '2500' VA. Converted exactly to website base unit; W and VA not interchanged. Official source ↗ |
| Connection phases | three-phase Official source ↗ | 1Connection phase count bound to Task10 exact identity (single-phase); nominal wiring/voltage evidence retained. Official source ↗ |
| PV input & tracking | ||
| Independent MPPT trackers | 2 Official source ↗ | 1MPP tracker count; exact model/market Task10 evidence reused. Official source ↗ |
| MPPT operating window minimum | 80 VReviewed MPPT/usable MPP operating window minimum Official source ↗ | 40 VMPPT operating range; endpoint of exact official range [40, 550], not the absolute DC limit. Official source ↗ |
| MPPT operating window maximum | 800 VReviewed MPPT/usable MPP operating window maximum Official source ↗ | 550 VMPPT operating range; endpoint of exact official range [40, 550], not the absolute DC limit. Official source ↗ |
| DC operating voltage minimum | Unknown | Unknown |
| DC operating voltage maximum | Unknown | Unknown |
| Maximum PV input voltage | 1000 V Official source ↗ | 600 Vmaximum PV input voltage; exact model/market Task10 evidence reused. Official source ↗ |
| Maximum input current per tracker/input | MPPT1 12.5 / MPPT2 12.5 A Official source ↗ | 16 ADC input current per MPPT, not total inverter current; per-MPPT/input maximum, not total inverter current. Official source ↗ |
| Maximum PV short-circuit current | MPPT1 20 / MPPT2 20 A Official source ↗ | 25 ADC short-circuit current per MPPT; per-MPPT/input maximum, not total inverter current. Official source ↗ |
| Efficiency & environment | ||
| Maximum conversion efficiency | 98.2 % Official source ↗ | 97.6 %maximum efficiency; exact model/market Task10 evidence reused. Official source ↗ |
| European efficiency | Unknown | 97 %European efficiency; exact model/market Task10 evidence reused. Official source ↗ |
| Operating ambient temperature minimum | -25 °COperating ambient temperature minimum Official source ↗ | -25 °Coperating temperature range; lower endpoint of exact official range [-25, 60]. Official source ↗ |
| Operating ambient temperature maximum | 60 °COperating ambient temperature maximum Official source ↗ | 60 °Coperating temperature range; upper endpoint of exact official range [-25, 60]. Official source ↗ |
| Enclosure protection | IP66 Official source ↗ | IP66Official exact-model enclosure ingress-protection rating; no environmental design approval implied. Official source ↗ |
| Surge protection | Unknown | DC: Type III (Type II optional); AC: Type III (Type II optional)Official exact-model/family surge-protection rows; optional Type II upgrade retained where stated. Official source ↗ |
| Warranty | ||
| Warranty and eligibility | Unknown | Unknown |