String inverter 3 exact records
Edit selection
Inverter electrical comparison
SpecificationMOD 5000TL3-XGrowatt New Energy · Global / ROW (Growatt English Worldwide catalog)Deep comparison fields reviewedR110-G2Fox ESS · Global / ROW official siteDeep comparison fields reviewedS2500-G3Fox ESS · Global / ROW official siteDeep comparison fields reviewed
AC output
Rated AC active power5000 Wrated/nominal AC active output power Raw/footnote context: 5000W
Official source ↗
110000 Wrated active AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
2500 Wnominal active AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Maximum AC apparent output5500 VAmaximum AC apparent output power Raw/footnote context: 5500VA
Official source ↗
121000 VAmaximum apparent AC output for stated market; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
2750 VAmaximum apparent AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Connection phases3Task10 exact-model evidence records phase as 'Three phase'; normalized to 3 connection phase(s). Identity/category source is official Growatt evidence; no grid approval inferred. Raw/footnote context: Type II
Official source ↗
3Official exact-model/family phase identity: three-phase. For North-American split-phase, the literal split-phase descriptor is retained rather than converted to a false phase count. No grid-approval inference.
Official source ↗
1Official exact-model/family phase identity: single-phase. For North-American split-phase, the literal split-phase descriptor is retained rather than converted to a false phase count. No grid-approval inference.
Official source ↗
PV input & tracking
Independent MPPT trackers2independent MPP tracker count Raw/footnote context: 2
Official source ↗
10Integrated independent MPP tracker count; exact R(G2) model grouping
Official source ↗
1independent MPP trackers; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
MPPT operating window minimum140 VMPPT operating voltage range; not full-power range unless explicitly stated; lower bound of the manufacturer MPPT operating range. Raw/footnote context: 140-1000V
Official source ↗
200 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
50 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
MPPT operating window maximum1000 VMPPT operating voltage range; not full-power range unless explicitly stated; upper bound of the manufacturer MPPT operating range. Raw/footnote context: 140-1000V
Official source ↗
1000 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
480 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
DC operating voltage minimumUnknownUnknownUnknown
DC operating voltage maximumUnknownUnknownUnknown
Maximum PV input voltage1100 Vmaximum DC input voltage Raw/footnote context: 1100V
Official source ↗
1100 Vmaximum DC input voltage; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
500 Vmaximum DC input voltage; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Maximum input current per tracker/input13 Amaximum input current at MPP-tracker scope Raw/footnote context: 13A
Official source ↗
40 Amaximum input current at source scope; scope: source table scope; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
20 Amaximum input current; scope: input; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Maximum PV short-circuit current16 Amaximum short-circuit current at MPP-tracker scope Raw/footnote context: 16A
Official source ↗
50 Amaximum short-circuit current at source scope; scope: source table scope; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
26 Amaximum short-circuit current; scope: input; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Efficiency & environment
Maximum conversion efficiency98.3 %maximum efficiency Raw/footnote context: 98.3%
Official source ↗
98.6 %maximum conversion efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
97.4 %maximum conversion efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
European efficiency97.5 %European efficiency Raw/footnote context: 97.5%
Official source ↗
98.2 %European efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
96.8 %European efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Operating ambient temperature minimum-25 °Cambient operating temperature range; lower ambient operating-temperature bound. Raw/footnote context: -25°C...+60°C
Official source ↗
-30 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
-25 °Cambient operating range; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Operating ambient temperature maximum60 °Cambient operating temperature range; upper ambient operating-temperature bound. Raw/footnote context: -25°C...+60°C
Official source ↗
60 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
60 °Cambient operating range; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Enclosure protectionIP66ip rating Raw/footnote context: IP66
Official source ↗
IP66ingress protection rating; scope: enclosure; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
IP65ingress protection rating; scope: enclosure; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Surge protectionDC: Type II; AC: Type IIManufacturer-published surge-protection rows; AC/DC scope preserved exactly. No safety approval inferred. Raw/footnote context: Type II | Type II
Official source ↗
DC Type II / AC Type IIManufacturer protection table; optional qualifiers retained where stated. Decorative/catalogue use only; no safety approval.
Official source ↗
DC Type II / AC Type II (optional)Manufacturer protection table; optional qualifiers retained where stated. Decorative/catalogue use only; no safety approval.
Official source ↗
Warranty
Warranty and eligibility5 years standard; 10 years optionalstandard/optional warranty duration Raw/footnote context: 5 years / 10 years optional
Official source ↗
UnknownUnknown