Compare inverters.
Exact market specifications side by side, limited to one reviewed comparison category.
Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.
Hybrid / smart energy inverter
2 exact records
Edit selection
| Specification | X3-NEO-15K-LVSolaX Power · Global / ROWDeep comparison fields reviewed | WIT 20K-HUGrowatt New Energy · Global / ROWDeep comparison fields reviewed |
|---|---|---|
| AC output | ||
| Rated AC active power | 15000 WManufacturer-published exact-model value; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Official source ↗ | 20000 Wrated AC active output power Official source ↗ |
| Maximum AC apparent output | 16500 VAexact model column, manufacturer datasheet Official source ↗ | 22000 VAmaximum AC apparent power Official source ↗ |
| Connection phases | 3Connection phase stated by the exact official family/model evidence and Task10 exact identity record; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Official source ↗ | three_phaseExact model/market phase classification retained from Task10 source-worker review; no cross-model interpolation. Official source ↗ |
| PV input & tracking | ||
| Independent MPPT trackers | 2exact model column, manufacturer datasheet Official source ↗ | 2MPP tracker count as published for 17–25 kW table Official source ↗ |
| MPPT operating window minimum | Unknown | 150 VMPPT operating voltage range Official source ↗ |
| MPPT operating window maximum | Unknown | 850 VMPPT operating voltage range Official source ↗ |
| DC operating voltage minimum | 160 VManufacturer-published exact-model value; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Official source ↗ | Unknown |
| DC operating voltage maximum | 950 VManufacturer-published exact-model value; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Official source ↗ | Unknown |
| Maximum PV input voltage | 1000 VManufacturer-published exact-model value; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Official source ↗ | 1000 Vmaximum PV input voltage Official source ↗ |
| Maximum input current per tracker/input | 36 / 36 Aexact model column, manufacturer datasheet Official source ↗ | 40 Amaximum PV input current per MPPT Official source ↗ |
| Maximum PV short-circuit current | 50 / 50 Aexact model column, manufacturer datasheet Official source ↗ | 50 Amaximum PV short-circuit current per MPPT Official source ↗ |
| Efficiency & environment | ||
| Maximum conversion efficiency | 97.6 %exact model column, manufacturer datasheet Official source ↗ | 97.6 %maximum efficiency Official source ↗ |
| European efficiency | Unknown | Unknown |
| Operating ambient temperature minimum | -25 °Cexact model column, manufacturer datasheet Official source ↗ | -30 °Coperating ambient range Official source ↗ |
| Operating ambient temperature maximum | 60 °Cexact model column, manufacturer datasheet Official source ↗ | 60 °Coperating ambient range Official source ↗ |
| Enclosure protection | IP65exact model column, manufacturer datasheet Official source ↗ | IP66enclosure ingress protection Official source ↗ |
| Surge protection | Unknown | Unknown |
| Warranty | ||
| Warranty and eligibility | Unknown | 5 / 10Manufacturer warranty statement/options as published; eligibility and local terms may vary and are not independently granted by this catalogue review. QC schema normalization: canonical display-field unit is ''; original Task18 unit metadata was 'years'. The value semantics are preserved in the field value/test condition. Official source ↗ |