Compare inverters.
Exact market specifications side by side, limited to one reviewed comparison category.
Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.
Hybrid / smart energy inverter
2 exact records
Edit selection
| Specification | SUN2000-4KTL-M1Huawei Digital Power / FusionSolar · Pakistan localized current pageDeep comparison fields reviewed | X1-Lite-12K-LVSolaX Power · Global / ROWDeep comparison fields reviewed |
|---|---|---|
| AC output | ||
| Rated AC active power | 4000 Wrated on-grid output Official source ↗ | 12000 WManufacturer-published exact-model value; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Official source ↗ |
| Maximum AC apparent output | 4400 VAmaximum apparent power; grid-code footnote applies to 10K Official source ↗ | 13200 VAexact model column, manufacturer datasheet Official source ↗ |
| Connection phases | three-phasegrid connection Official source ↗ | 1Connection phase stated by the exact official family/model evidence and Task10 exact identity record; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Official source ↗ |
| PV input & tracking | ||
| Independent MPPT trackers | 2MPP trackers Official source ↗ | 3Manufacturer-published exact-model value; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Official source ↗ |
| MPPT operating window minimum | 140 VReviewed MPPT/usable MPP operating window minimum Official source ↗ | Unknown |
| MPPT operating window maximum | 980 VReviewed MPPT/usable MPP operating window maximum Official source ↗ | Unknown |
| DC operating voltage minimum | Unknown | 50 VManufacturer-published exact-model value; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Official source ↗ |
| DC operating voltage maximum | Unknown | 550 VManufacturer-published exact-model value; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Official source ↗ |
| Maximum PV input voltage | 1100 Vmaximum input voltage Official source ↗ | 600 Vexact model column, manufacturer datasheet Official source ↗ |
| Maximum input current per tracker/input | 13.5 Aper MPPT Official source ↗ | 32 AManufacturer-published exact-model value; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Official source ↗ |
| Maximum PV short-circuit current | 19.5 Amaximum short-circuit current Official source ↗ | 40 / 40 / 40 Aexact model column, manufacturer datasheet Official source ↗ |
| Efficiency & environment | ||
| Maximum conversion efficiency | 98.3 %maximum efficiency Official source ↗ | 97.6 %exact model column, manufacturer datasheet Official source ↗ |
| European efficiency | 97.1 %European weighted efficiency Official source ↗ | Unknown |
| Operating ambient temperature minimum | -25 °COperating ambient temperature minimum Official source ↗ | -25 °Cexact model column, manufacturer datasheet Official source ↗ |
| Operating ambient temperature maximum | 60 °COperating ambient temperature maximum Official source ↗ | 60 °Cexact model column, manufacturer datasheet Official source ↗ |
| Enclosure protection | IP65protection rating Official source ↗ | IP65exact model column, manufacturer datasheet Official source ↗ |
| Surge protection | Unknown | Unknown |
| Warranty | ||
| Warranty and eligibility | Unknown | Unknown |