PUBLIC CATALOGUE • 632 comparison-ready inverter records. Incomplete identities are not shown.
← Choose inverters

Compare inverters.

Exact market specifications side by side, limited to one reviewed comparison category.

Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.

String inverter 2 exact records · Differences include rating conditions and scope.
Edit selection
Inverter electrical comparison
SpecificationGW3000-XS-30GoodWe Technologies Co., Ltd. · Global / current international catalogDeep comparison fields reviewedT10-MFox ESS · Global / ROW official siteDeep comparison fields reviewed
AC output
Rated AC active power3000 Wnominal output active power; exact source raw value '3000' W. Converted exactly to website base unit; W and VA not interchanged.
Source unit W
Official source ↗
User Manual V1.9 Technical Parameters pp.53-58 exact-model column
Revision V1.9 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

10000 Wrated active AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit W
Official source ↗
p.2 Rated Output Power
Revision V1.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Maximum AC apparent output3000 VAmaximum AC apparent power; exact source raw value '3000' VA. Converted exactly to website base unit; W and VA not interchanged.
Source unit VA
Official source ↗
User Manual V1.9 Technical Parameters pp.53-58 exact-model column
Revision V1.9 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

11000 VAmaximum apparent AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit VA
Official source ↗
p.2 Max. Apparent Power
Revision V1.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Connection phases1Connection phase count bound to Task10 exact identity (single-phase); nominal wiring/voltage evidence retained.
Official source ↗
User Manual V1.9 Technical Parameters pp.53-58 exact-model column
Revision V1.9 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

3Official exact-model/family phase identity: three-phase. For North-American split-phase, the literal split-phase descriptor is retained rather than converted to a false phase count. No grid-approval inference.
Official source ↗
p.2 AC OUTPUT — Nominal Voltage 415/240 V; 400/230 V; 380/220 V, 3L/N/PE; exact model column
Revision V1.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

PV input & tracking
Independent MPPT trackers1MPP tracker count; exact model/market Task10 evidence reused.
Official source ↗
User Manual V1.9 Technical Parameters pp.53-58 exact-model column
Revision V1.9 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

2independent MPP trackers; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
p.2 No. of MPP Trackers
Revision V1.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

MPPT operating window minimum40 VMPPT operating range; endpoint of exact official range [40, 550], not the absolute DC limit.
Source unit V
Official source ↗
User Manual V1.9 Technical Parameters pp.53-58 exact-model column
Revision V1.9 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

140 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit V
Official source ↗
p.2 MPPT Voltage Range; canonical min bound from source range
Revision V1.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

MPPT operating window maximum550 VMPPT operating range; endpoint of exact official range [40, 550], not the absolute DC limit.
Source unit V
Official source ↗
User Manual V1.9 Technical Parameters pp.53-58 exact-model column
Revision V1.9 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

1000 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit V
Official source ↗
p.2 MPPT Voltage Range; canonical max bound from source range
Revision V1.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

DC operating voltage minimumUnknownUnknown
DC operating voltage maximumUnknownUnknown
Maximum PV input voltage600 Vmaximum PV input voltage; exact model/market Task10 evidence reused.
Source unit V
Official source ↗
User Manual V1.9 Technical Parameters pp.53-58 exact-model column
Revision V1.9 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

1100 Vmaximum DC input voltage; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit V
Official source ↗
p.2 Max. Input Voltage; note max operating 1020V
Revision V1.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Maximum input current per tracker/input16 ADC input current per MPPT, not total inverter current; per-MPPT/input maximum, not total inverter current.
Source unit A
Official source ↗
User Manual V1.9 Technical Parameters pp.53-58 exact-model column
Revision V1.9 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

20 / 20 Amaximum input current by tracker; scope: MPPT1/MPPT2; raw source cell retained: 20/20; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit A
Official source ↗
p.2 model-specific Max. Input Current
Revision V1.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Maximum PV short-circuit current25 ADC short-circuit current per MPPT; per-MPPT/input maximum, not total inverter current.
Source unit A
Official source ↗
User Manual V1.9 Technical Parameters pp.53-58 exact-model column
Revision V1.9 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

25 / 25 Amaximum short-circuit current by tracker; scope: MPPT1/MPPT2; raw source cell retained: 25/25; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit A
Official source ↗
p.2 model-specific Max. Isc Current
Revision V1.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Efficiency & environment
Maximum conversion efficiency97.6 %maximum efficiency; exact model/market Task10 evidence reused.
Source unit %
Official source ↗
User Manual V1.9 Technical Parameters pp.53-58 exact-model column
Revision V1.9 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

98.6 %maximum conversion efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit %
Official source ↗
p.2 Max. Efficiency
Revision V1.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

European efficiency97.1 %European efficiency; exact model/market Task10 evidence reused.
Source unit %
Official source ↗
User Manual V1.9 Technical Parameters pp.53-58 exact-model column
Revision V1.9 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

97.8 %European efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit %
Official source ↗
p.2 European Efficiency
Revision V1.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Operating ambient temperature minimum-25 °Coperating temperature range; lower endpoint of exact official range [-25, 60].
Source unit °C
Official source ↗
User Manual V1.9 Technical Parameters pp.53-58 exact-model column
Revision V1.9 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

-25 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit °C
Official source ↗
p.2 Operating Temperature Range; canonical min bound from source range
Revision V1.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Operating ambient temperature maximum60 °Coperating temperature range; upper endpoint of exact official range [-25, 60].
Source unit °C
Official source ↗
User Manual V1.9 Technical Parameters pp.53-58 exact-model column
Revision V1.9 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

60 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit °C
Official source ↗
p.2 Operating Temperature Range; canonical max bound from source range
Revision V1.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Enclosure protectionIP66Official exact-model enclosure ingress-protection rating; no environmental design approval implied.
Official source ↗
User Manual V1.9 Technical Parameters pp.53-58 exact-model column
Revision V1.9 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

IP65ingress protection rating; scope: enclosure; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
p.2 Ingress Protection
Revision V1.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Surge protectionDC: Type III (Type II optional); AC: Type III (Type II optional)Official exact-model/family surge-protection rows; optional Type II upgrade retained where stated.
Official source ↗
XS G3 current official global technical data: DC Surge Protection and AC Surge Protection rows.
Revision GoodWe-Single page-20250703-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

DC Type II / AC Type IIManufacturer protection table; optional qualifiers retained where stated. Decorative/catalogue use only; no safety approval.
Official source ↗
p.2 PROTECTION — DC/AC Surge Protection row
Revision V1.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Warranty
Warranty and eligibilityUnknownUnknown