Compare inverters.
Exact market specifications side by side, limited to one reviewed comparison category.
Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.
| Specification | GW3000-XS-30GoodWe Technologies Co., Ltd. · Global / current international catalogDeep comparison fields reviewed | T10-MFox ESS · Global / ROW official siteDeep comparison fields reviewed |
|---|---|---|
| AC output | ||
| Rated AC active power | 3000 Wnominal output active power; exact source raw value '3000' W. Converted exactly to website base unit; W and VA not interchanged. Source unit W Official source ↗ User Manual V1.9 Technical Parameters pp.53-58 exact-model column Revision V1.9 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 10000 Wrated active AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit W Official source ↗ p.2 Rated Output Power Revision V1.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Maximum AC apparent output | 3000 VAmaximum AC apparent power; exact source raw value '3000' VA. Converted exactly to website base unit; W and VA not interchanged. Source unit VA Official source ↗ User Manual V1.9 Technical Parameters pp.53-58 exact-model column Revision V1.9 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 11000 VAmaximum apparent AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit VA Official source ↗ p.2 Max. Apparent Power Revision V1.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Connection phases | 1Connection phase count bound to Task10 exact identity (single-phase); nominal wiring/voltage evidence retained. Official source ↗ User Manual V1.9 Technical Parameters pp.53-58 exact-model column Revision V1.9 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 3Official exact-model/family phase identity: three-phase. For North-American split-phase, the literal split-phase descriptor is retained rather than converted to a false phase count. No grid-approval inference. Official source ↗ p.2 AC OUTPUT — Nominal Voltage 415/240 V; 400/230 V; 380/220 V, 3L/N/PE; exact model column Revision V1.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| PV input & tracking | ||
| Independent MPPT trackers | 1MPP tracker count; exact model/market Task10 evidence reused. Official source ↗ User Manual V1.9 Technical Parameters pp.53-58 exact-model column Revision V1.9 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 2independent MPP trackers; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ p.2 No. of MPP Trackers Revision V1.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| MPPT operating window minimum | 40 VMPPT operating range; endpoint of exact official range [40, 550], not the absolute DC limit. Source unit V Official source ↗ User Manual V1.9 Technical Parameters pp.53-58 exact-model column Revision V1.9 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 140 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit V Official source ↗ p.2 MPPT Voltage Range; canonical min bound from source range Revision V1.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| MPPT operating window maximum | 550 VMPPT operating range; endpoint of exact official range [40, 550], not the absolute DC limit. Source unit V Official source ↗ User Manual V1.9 Technical Parameters pp.53-58 exact-model column Revision V1.9 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 1000 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit V Official source ↗ p.2 MPPT Voltage Range; canonical max bound from source range Revision V1.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| DC operating voltage minimum | Unknown | Unknown |
| DC operating voltage maximum | Unknown | Unknown |
| Maximum PV input voltage | 600 Vmaximum PV input voltage; exact model/market Task10 evidence reused. Source unit V Official source ↗ User Manual V1.9 Technical Parameters pp.53-58 exact-model column Revision V1.9 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 1100 Vmaximum DC input voltage; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit V Official source ↗ p.2 Max. Input Voltage; note max operating 1020V Revision V1.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Maximum input current per tracker/input | 16 ADC input current per MPPT, not total inverter current; per-MPPT/input maximum, not total inverter current. Source unit A Official source ↗ User Manual V1.9 Technical Parameters pp.53-58 exact-model column Revision V1.9 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 20 / 20 Amaximum input current by tracker; scope: MPPT1/MPPT2; raw source cell retained: 20/20; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit A Official source ↗ p.2 model-specific Max. Input Current Revision V1.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Maximum PV short-circuit current | 25 ADC short-circuit current per MPPT; per-MPPT/input maximum, not total inverter current. Source unit A Official source ↗ User Manual V1.9 Technical Parameters pp.53-58 exact-model column Revision V1.9 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 25 / 25 Amaximum short-circuit current by tracker; scope: MPPT1/MPPT2; raw source cell retained: 25/25; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit A Official source ↗ p.2 model-specific Max. Isc Current Revision V1.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Efficiency & environment | ||
| Maximum conversion efficiency | 97.6 %maximum efficiency; exact model/market Task10 evidence reused. Source unit % Official source ↗ User Manual V1.9 Technical Parameters pp.53-58 exact-model column Revision V1.9 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 98.6 %maximum conversion efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit % Official source ↗ p.2 Max. Efficiency Revision V1.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| European efficiency | 97.1 %European efficiency; exact model/market Task10 evidence reused. Source unit % Official source ↗ User Manual V1.9 Technical Parameters pp.53-58 exact-model column Revision V1.9 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 97.8 %European efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit % Official source ↗ p.2 European Efficiency Revision V1.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Operating ambient temperature minimum | -25 °Coperating temperature range; lower endpoint of exact official range [-25, 60]. Source unit °C Official source ↗ User Manual V1.9 Technical Parameters pp.53-58 exact-model column Revision V1.9 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | -25 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit °C Official source ↗ p.2 Operating Temperature Range; canonical min bound from source range Revision V1.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Operating ambient temperature maximum | 60 °Coperating temperature range; upper endpoint of exact official range [-25, 60]. Source unit °C Official source ↗ User Manual V1.9 Technical Parameters pp.53-58 exact-model column Revision V1.9 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 60 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit °C Official source ↗ p.2 Operating Temperature Range; canonical max bound from source range Revision V1.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Enclosure protection | IP66Official exact-model enclosure ingress-protection rating; no environmental design approval implied. Official source ↗ User Manual V1.9 Technical Parameters pp.53-58 exact-model column Revision V1.9 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | IP65ingress protection rating; scope: enclosure; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ p.2 Ingress Protection Revision V1.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Surge protection | DC: Type III (Type II optional); AC: Type III (Type II optional)Official exact-model/family surge-protection rows; optional Type II upgrade retained where stated. Official source ↗ XS G3 current official global technical data: DC Surge Protection and AC Surge Protection rows. Revision GoodWe-Single page-20250703-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | DC Type II / AC Type IIManufacturer protection table; optional qualifiers retained where stated. Decorative/catalogue use only; no safety approval. Official source ↗ p.2 PROTECTION — DC/AC Surge Protection row Revision V1.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Warranty | ||
| Warranty and eligibility | Unknown | Unknown |