PUBLIC CATALOGUE • 632 comparison-ready inverter records. Incomplete identities are not shown.
← Choose inverters

Compare inverters.

Exact market specifications side by side, limited to one reviewed comparison category.

Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.

Microinverter 3 exact records
Edit selection
Inverter electrical comparison
SpecificationEZ1-HAPsystems · PhilippinesDeep comparison fields reviewedQT2APsystems · APACDeep comparison fields reviewedEZ1-MAPsystems · EMEADeep comparison fields reviewed
AC output
Rated AC active powerUnknownUnknownUnknown
Maximum AC apparent output960 VAmaximum continuous apparent output; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
2000 VAMaximum Continuous Output Power
Official source ↗
799 VAmaximum continuous apparent output; EZ1-M factory default 600 VA; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
Connection phases1Connection phase stated by the exact official family/model evidence and Task10 exact identity record; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
Unknown1Connection phase stated by the exact official family/model evidence and Task10 exact identity record; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
PV input & tracking
Independent MPPT trackers2two independent input MPPTs; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
2official datasheet product feature: 4 DC inputs, 2 MPPTs
Official source ↗
2two independent inputs/MPPT; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
MPPT operating window minimum28 Vmanufacturer-published text/range; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
30 VPeak Power Tracking Voltage
Official source ↗
28 Vmanufacturer-published text/range; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
MPPT operating window maximum45 Vmanufacturer-published text/range; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
45 VPeak Power Tracking Voltage
Official source ↗
45 Vmanufacturer-published text/range; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
DC operating voltage minimumUnknown26 VOperating Voltage Range
Official source ↗
Unknown
DC operating voltage maximumUnknown60 VOperating Voltage Range
Official source ↗
Unknown
Maximum PV input voltage60 Vmaximum input voltage; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
60 VMaximum Input Voltage
Official source ↗
60 Vmaximum input voltage; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
Maximum input current per tracker/input20 Amaximum input current; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
20 A20A × 4 inputs; normalized per input
Official source ↗
20 Amaximum input current; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
Maximum PV short-circuit current25 AIsc PV; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
25 AIsc PV 25A × 4; normalized per input
Official source ↗
25 AIsc PV; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
Efficiency & environment
Maximum conversion efficiency96 %peak efficiency; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
96.5 %Peak Efficiency
Official source ↗
96.7 %peak efficiency; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
European efficiencyUnknownUnknownUnknown
Operating ambient temperature minimum-40 °Cmanufacturer-published text/range; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
-40 °COperating Ambient Temperature Range
Official source ↗
-40 °COperating ambient temperature range minimum; exact EMEA BC01 variant
Official source ↗
Operating ambient temperature maximum65 °Cmanufacturer-published text/range; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
65 °COperating Ambient Temperature Range
Official source ↗
65 °COperating ambient temperature range maximum; exact EMEA BC01 variant
Official source ↗
Enclosure protectionIP67manufacturer-published text/range; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
IP67Enclosure Environmental Rating
Official source ↗
IP67manufacturer-published text/range; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
Surge protectionUnknownUnknownUnknown
Warranty
Warranty and eligibility12 yearsstandard warranty; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
12 years12 Years Standard
Official source ↗
12 yearsstandard warranty; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗