PUBLIC CATALOGUE • 632 comparison-ready inverter records. Incomplete identities are not shown.
← Choose inverters

Compare inverters.

Exact market specifications side by side, limited to one reviewed comparison category.

Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.

Hybrid / smart energy inverter 3 exact records
Edit selection
Inverter electrical comparison
SpecificationGW6000-ES-C10GoodWe Technologies Co., Ltd. · Global / ROW (GoodWe global site; regional footnotes retained)Deep comparison fields reviewedH1-3.7-E-G2-WLFox ESS · United Kingdom / G98 configuration — exact hybrid modelDeep comparison fields reviewedH3-5.0-SmartFox ESS · Global / ROW official siteDeep comparison fields reviewed
AC output
Rated AC active power6000 Wnominal/rated active power; exact source raw value '6.0' kW. Converted exactly to website base unit; W and VA not interchanged.
Official source ↗
3680 Wrated active AC output; scope: grid AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
5000 Wnominal active AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Maximum AC apparent output6600 VAmaximum apparent power; exact source raw value '6.6' kVA. Converted exactly to website base unit; W and VA not interchanged.
Official source ↗
3680 VAmaximum apparent AC output for stated market/grid variant; scope: grid AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
5500 VAmaximum apparent AC output for stated market; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Connection phases1Connection phase count bound to Task10 exact identity (Single phase); nominal wiring/voltage evidence retained.
Official source ↗
1Official exact-model/family phase identity: single-phase. For North-American split-phase, the literal split-phase descriptor is retained rather than converted to a false phase count. No grid-approval inference.
Official source ↗
3Official exact-model/family phase identity: three-phase. For North-American split-phase, the literal split-phase descriptor is retained rather than converted to a false phase count. No grid-approval inference.
Official source ↗
PV input & tracking
Independent MPPT trackers2count; exact model/market Task10 evidence reused.
Official source ↗
2independent MPP trackers; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
3independent MPP trackers; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
MPPT operating window minimum60 Voperating range; endpoint of exact official range [60, 550], not the absolute DC limit.
Official source ↗
80 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
120 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
MPPT operating window maximum550 Voperating range; endpoint of exact official range [60, 550], not the absolute DC limit.
Official source ↗
550 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
950 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
DC operating voltage minimumUnknownUnknownUnknown
DC operating voltage maximumUnknownUnknownUnknown
Maximum PV input voltage600 Vmaximum; exact model/market Task10 evidence reused.
Official source ↗
600 Vmaximum DC voltage; scope: PV input; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
1000 Vmaximum DC voltage; scope: PV input; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Maximum input current per tracker/input20 Aper-MPPT maximum; per-MPPT/input maximum, not total inverter current.
Official source ↗
16 / 16 Amaximum input current by tracker; scope: MPPT1/MPPT2; raw source cell retained: 16/16; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
20 / 20 / 20 Amaximum current by MPPT; scope: MPPT1/2/3; raw source cell retained: 20/20/20; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Maximum PV short-circuit current26 Aper-MPPT maximum; per-MPPT/input maximum, not total inverter current.
Official source ↗
20 / 20 Amaximum short-circuit current by tracker; scope: MPPT1/MPPT2; raw source cell retained: 20/20; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
25 / 25 / 25 Amaximum short-circuit current by MPPT; scope: MPPT1/2/3; raw source cell retained: 25/25/25; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Efficiency & environment
Maximum conversion efficiency97.6 %maximum efficiency; exact model/market Task10 evidence reused.
Official source ↗
97.08 %maximum conversion efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
97.3 %maximum conversion efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
European efficiency96.2 %European efficiency; exact model/market Task10 evidence reused.
Official source ↗
95.7 %European efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
97.2 %European efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Operating ambient temperature minimum-35 °Coperating range; lower endpoint of exact official range [-35, 60].
Official source ↗
-25 °Cambient operating range; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
-25 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Operating ambient temperature maximum60 °Coperating range; upper endpoint of exact official range [-35, 60].
Official source ↗
60 °Cambient operating range; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
60 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Enclosure protectionIP66Official enclosure ingress-protection rating; catalogue description only, not a safety or suitability approval.
Official source ↗
IP65ingress protection rating; scope: enclosure; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
IP65ingress protection rating; scope: enclosure; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Surge protectionDC: Type III; AC: Type IIIOfficial surge-protection configuration for this exact model family; optional enhancements are preserved verbatim where stated.
Official source ↗
DC Type II / AC Type IIIManufacturer protection table; optional qualifiers retained where stated. Decorative/catalogue use only; no safety approval.
Official source ↗
DC Type II / AC Type IIManufacturer protection table; optional qualifiers retained where stated. Decorative/catalogue use only; no safety approval.
Official source ↗
Warranty
Warranty and eligibilityUnknownUnknownUnknown