Compare inverters.
Exact market specifications side by side, limited to one reviewed comparison category.
Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.
String inverter
2 exact records
Edit selection
| Specification | MOD 10KTL3-XGrowatt New Energy · Global / ROW (Growatt English Worldwide catalog)Deep comparison fields reviewed | Tauro ECO 50-3-DFronius International GmbH · Global/International current Help Center; 380/220–400/230 V classDeep comparison fields reviewed |
|---|---|---|
| AC output | ||
| Rated AC active power | 10000 WManufacturer exact-model specification as published; no compatibility, string-sizing, grid, design, safety, or live-publication approval. Official source ↗ | 50000 W Official source ↗ |
| Maximum AC apparent output | 11000 VAManufacturer exact-model specification as published; no compatibility, string-sizing, grid, design, safety, or live-publication approval. Official source ↗ | 50000 VA Official source ↗ |
| Connection phases | three_phaseExact model/market phase classification retained from Task10 source-worker review; no cross-model interpolation. Official source ↗ | three-phase Official source ↗ |
| PV input & tracking | ||
| Independent MPPT trackers | 2Manufacturer exact-model specification as published; no compatibility, string-sizing, grid, design, safety, or live-publication approval. Official source ↗ | 1 Official source ↗ |
| MPPT operating window minimum | 140 VManufacturer exact-model specification as published; no compatibility, string-sizing, grid, design, safety, or live-publication approval. Official source ↗ | 580 VReviewed MPPT/usable MPP operating window minimum Official source ↗ |
| MPPT operating window maximum | 1000 VManufacturer exact-model specification as published; no compatibility, string-sizing, grid, design, safety, or live-publication approval. Official source ↗ | 930 VReviewed MPPT/usable MPP operating window maximum Official source ↗ |
| DC operating voltage minimum | Unknown | 580 VPublished DC input/operating range minimum; not relabelled as MPPT Official source ↗ |
| DC operating voltage maximum | Unknown | 1000 VPublished DC input/operating range maximum; not relabelled as MPPT Official source ↗ |
| Maximum PV input voltage | 1100 VManufacturer exact-model specification as published; no compatibility, string-sizing, grid, design, safety, or live-publication approval. Official source ↗ | 1000 V Official source ↗ |
| Maximum input current per tracker/input | 13 / 13 AManufacturer exact-model specification as published; no compatibility, string-sizing, grid, design, safety, or live-publication approval. Official source ↗ | 14.5 A Official source ↗ |
| Maximum PV short-circuit current | 16 / 16 AManufacturer exact-model specification as published; no compatibility, string-sizing, grid, design, safety, or live-publication approval. Official source ↗ | 20 A Official source ↗ |
| Efficiency & environment | ||
| Maximum conversion efficiency | 98.6 %Manufacturer exact-model specification as published; no compatibility, string-sizing, grid, design, safety, or live-publication approval. Official source ↗ | 98.5 % Official source ↗ |
| European efficiency | 98.1 %Manufacturer exact-model specification as published; no compatibility, string-sizing, grid, design, safety, or live-publication approval. Official source ↗ | Unknown |
| Operating ambient temperature minimum | -25 °CManufacturer exact-model specification as published; no compatibility, string-sizing, grid, design, safety, or live-publication approval. Official source ↗ | -40 °COperating ambient temperature minimum Official source ↗ |
| Operating ambient temperature maximum | 60 °CManufacturer exact-model specification as published; no compatibility, string-sizing, grid, design, safety, or live-publication approval. Official source ↗ | 65 °COperating ambient temperature maximum Official source ↗ |
| Enclosure protection | IP66Manufacturer exact-model specification as published; no compatibility, string-sizing, grid, design, safety, or live-publication approval. Official source ↗ | IP65 Official source ↗ |
| Surge protection | DC Type II / AC Type IIPublished DC/AC surge-protection types preserved separately; no safety approval is implied. Official source ↗ | Unknown |
| Warranty | ||
| Warranty and eligibility | standard 5 / optional 10Manufacturer warranty statement/options as published; eligibility and local terms may vary and are not independently granted by this catalogue review. QC schema normalization: canonical display-field unit is ''; original Task18 unit metadata was 'years'. The value semantics are preserved in the field value/test condition. Official source ↗ | Unknown |