PUBLIC CATALOGUE • 632 comparison-ready inverter records. Incomplete identities are not shown.
← Choose inverters

Compare inverters.

Exact market specifications side by side, limited to one reviewed comparison category.

Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.

Hybrid / smart energy inverter 2 exact records
Edit selection
Inverter electrical comparison
SpecificationSPH 4600TL BL-UPGrowatt New Energy · Global / ROWDeep comparison fields reviewedX3-HYBRID-15.0-DSolaX Power · Global / ROWDeep comparison fields reviewed
AC output
Rated AC active power4600 Wnominal AC output power
Official source ↗
15000 WRated output power (on-grid)
Official source ↗
Maximum AC apparent output4600 VAmaximum AC apparent power
Official source ↗
15000 VAMaximum output apparent power (on-grid)
Official source ↗
Connection phasessingle_phaseExact model/market phase classification retained from Task10 source-worker review; no cross-model interpolation.
Official source ↗
33/N/PE AC system
Official source ↗
PV input & tracking
Independent MPPT trackers2independent MPP trackers
Official source ↗
2Number of MPP trackers
Official source ↗
MPPT operating window minimum120 VMPPT operating voltage range
Official source ↗
180 VMPPT voltage range (not a full-power MPPT range)
Official source ↗
MPPT operating window maximum550 VMPPT operating voltage range
Official source ↗
950 VMPPT voltage range (not a full-power MPPT range)
Official source ↗
DC operating voltage minimumUnknownUnknown
DC operating voltage maximumUnknownUnknown
Maximum PV input voltage550 VPV maximum input voltage
Official source ↗
1000 VMaximum PV input voltage; upper DC voltage limit
Official source ↗
Maximum input current per tracker/input13.5 Amaximum PV input current per MPPT
Official source ↗
28 / 16 AMPPT1/MPPT2 maximum input current
Official source ↗
Maximum PV short-circuit current16.9 Amaximum PV short-circuit current per MPPT
Official source ↗
35 / 20 AMPPT1/MPPT2 maximum input short-circuit current
Official source ↗
Efficiency & environment
Maximum conversion efficiency97.4 %maximum efficiency
Official source ↗
98 %Maximum conversion efficiency
Official source ↗
European efficiencyUnknown97.7 %European efficiency
Official source ↗
Operating ambient temperature minimum-25 °Coperating ambient range
Official source ↗
-35 °COperating ambient temperature range
Official source ↗
Operating ambient temperature maximum60 °Coperating ambient range
Official source ↗
60 °COperating ambient temperature range
Official source ↗
Enclosure protectionIP65enclosure ingress protection
Official source ↗
IP65Ingress protection
Official source ↗
Surge protectionUnknownUnknown
Warranty
Warranty and eligibility5 / 10Manufacturer warranty statement/options as published; eligibility and local terms may vary and are not independently granted by this catalogue review. QC schema normalization: canonical display-field unit is ''; original Task18 unit metadata was 'years'. The value semantics are preserved in the field value/test condition.
Official source ↗
Unknown