Compare inverters.
Exact market specifications side by side, limited to one reviewed comparison category.
Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.
String inverter
2 exact records
Edit selection
| Specification | GW100K-GT-L-G10GoodWe Technologies Co., Ltd. · 220 V nominal output settingDeep comparison fields reviewed | Tauro ECO 99-3-DFronius International GmbH · Global/International current Help Center; 380/220–400/230 V classDeep comparison fields reviewed |
|---|---|---|
| AC output | ||
| Rated AC active power | 95600 WNominal output power at 220V; exact source raw value '95.6 kW @ 220V' kW. Converted exactly to website base unit; W and VA not interchanged. Official source ↗ | 99990 W Official source ↗ |
| Maximum AC apparent output | 95600 VAMax apparent power at 220V; exact source raw value '95.6 kVA @ 220V' kVA. Converted exactly to website base unit; W and VA not interchanged. Official source ↗ | 99990 VA Official source ↗ |
| Connection phases | 3Connection phase count bound to Task10 exact identity (three-phase); nominal wiring/voltage evidence retained. Official source ↗ | three-phase Official source ↗ |
| PV input & tracking | ||
| Independent MPPT trackers | 10MPP trackers; exact model/market Task10 evidence reused. Official source ↗ | 1 Official source ↗ |
| MPPT operating window minimum | 180 VMPPT operating range; endpoint of exact official range [180, 900], not the absolute DC limit. Official source ↗ | 580 VReviewed MPPT/usable MPP operating window minimum Official source ↗ |
| MPPT operating window maximum | 900 VMPPT operating range; endpoint of exact official range [180, 900], not the absolute DC limit. Official source ↗ | 930 VReviewed MPPT/usable MPP operating window maximum Official source ↗ |
| DC operating voltage minimum | Unknown | 580 VPublished DC input/operating range minimum; not relabelled as MPPT Official source ↗ |
| DC operating voltage maximum | Unknown | 1000 VPublished DC input/operating range maximum; not relabelled as MPPT Official source ↗ |
| Maximum PV input voltage | 900 VMax input voltage; exact model/market Task10 evidence reused. Official source ↗ | 1000 V Official source ↗ |
| Maximum input current per tracker/input | 42 AMax input current per MPPT; per-MPPT/input maximum, not total inverter current. Official source ↗ | 14.5 A Official source ↗ |
| Maximum PV short-circuit current | 52.5 AMax short circuit current per MPPT; per-MPPT/input maximum, not total inverter current. Official source ↗ | 20 A Official source ↗ |
| Efficiency & environment | ||
| Maximum conversion efficiency | 98.8 %Max efficiency; exact model/market Task10 evidence reused. Official source ↗ | 98.5 % Official source ↗ |
| European efficiency | 98.3 %European efficiency; exact model/market Task10 evidence reused. Official source ↗ | Unknown |
| Operating ambient temperature minimum | -30 °COperating temp; lower endpoint of exact official range [-30, 60]. Official source ↗ | -40 °COperating ambient temperature minimum Official source ↗ |
| Operating ambient temperature maximum | 60 °COperating temp; upper endpoint of exact official range [-30, 60]. Official source ↗ | 65 °COperating ambient temperature maximum Official source ↗ |
| Enclosure protection | IP66Official enclosure ingress-protection rating; catalogue description only, not a safety or suitability approval. Official source ↗ | IP65 Official source ↗ |
| Surge protection | DC: Type II (Type I + II optional); AC: Type IIOfficial surge-protection configuration for this exact model family; optional enhancements are preserved verbatim where stated. Official source ↗ | Unknown |
| Warranty | ||
| Warranty and eligibility | Unknown | Unknown |