Compare inverters.
Exact market specifications side by side, limited to one reviewed comparison category.
Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.
String inverter
3 exact records
Edit selection
| Specification | SUN2000-30K-MC0Huawei Digital Power / FusionSolar · Spain localized current product/support pageDeep comparison fields reviewed | GW35K-SMT-L-G20GoodWe Technologies Co., Ltd. · Global catalog (country/grid exceptions separated as material variants)Deep comparison fields reviewed | S3300-G3Fox ESS · Global / ROW official siteDeep comparison fields reviewed |
|---|---|---|---|
| AC output | |||
| Rated AC active power | 30000 W Official source ↗ | 35000 WNominal output power; exact source raw value '35 kW' kW. Converted exactly to website base unit; W and VA not interchanged. Official source ↗ | 3300 Wnominal active AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| Maximum AC apparent output | 33000 VA Official source ↗ | 38500 VAMax. AC apparent power; exact source raw value '38.5 kVA' kVA. Converted exactly to website base unit; W and VA not interchanged. Official source ↗ | 4000 VAmaximum apparent AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| Connection phases | three-phaseIssue 07, 2026-06-30 Official source ↗ | 3Connection phase count bound to Task10 exact identity (three-phase); nominal wiring/voltage evidence retained. Official source ↗ | 1Official exact-model/family phase identity: single-phase. For North-American split-phase, the literal split-phase descriptor is retained rather than converted to a false phase count. No grid-approval inference. Official source ↗ |
| PV input & tracking | |||
| Independent MPPT trackers | 4 Official source ↗ | 4MPP trackers; exact model/market Task10 evidence reused. Official source ↗ | 1independent MPP trackers; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| MPPT operating window minimum | 180 VReviewed MPPT/usable MPP operating window minimum Official source ↗ | 160 VMPPT operating range; endpoint of exact official range [160, 900], not the absolute DC limit. Official source ↗ | 50 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| MPPT operating window maximum | 1000 VReviewed MPPT/usable MPP operating window maximum Official source ↗ | 900 VMPPT operating range; endpoint of exact official range [160, 900], not the absolute DC limit. Official source ↗ | 480 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| DC operating voltage minimum | Unknown | Unknown | Unknown |
| DC operating voltage maximum | Unknown | Unknown | Unknown |
| Maximum PV input voltage | 1100 V Official source ↗ | 900 VMax. input voltage; exact model/market Task10 evidence reused. Official source ↗ | 500 Vmaximum DC input voltage; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| Maximum input current per tracker/input | 27 A Official source ↗ | 42 AMax. input current per MPPT; per-MPPT/input maximum, not total inverter current. Official source ↗ | 20 Amaximum input current; scope: input; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| Maximum PV short-circuit current | 40 A Official source ↗ | 52.5 AMax. short circuit current per MPPT; per-MPPT/input maximum, not total inverter current. Official source ↗ | 26 Amaximum short-circuit current; scope: input; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| Efficiency & environment | |||
| Maximum conversion efficiency | 98.6 % Official source ↗ | 98.4 %Max. efficiency; exact model/market Task10 evidence reused. Official source ↗ | 97.4 %maximum conversion efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| European efficiency | 98.4 % Official source ↗ | 98 %European efficiency; exact model/market Task10 evidence reused. Official source ↗ | 96.8 %European efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| Operating ambient temperature minimum | -25 °COperating ambient temperature minimum Official source ↗ | -30 °COperating temp; lower endpoint of exact official range [-30, 60]. Official source ↗ | -25 °Cambient operating range; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| Operating ambient temperature maximum | 60 °COperating ambient temperature maximum Official source ↗ | 60 °COperating temp; upper endpoint of exact official range [-30, 60]. Official source ↗ | 60 °Cambient operating range; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| Enclosure protection | IP66 Official source ↗ | IP66Official enclosure ingress-protection rating; catalogue description only, not a safety or suitability approval. Official source ↗ | IP65ingress protection rating; scope: enclosure; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| Surge protection | Unknown | DC: Type II (Type I + II optional); AC: Type IIOfficial surge-protection configuration for this exact model family; optional enhancements are preserved verbatim where stated. Official source ↗ | DC Type II / AC Type II (optional)Manufacturer protection table; optional qualifiers retained where stated. Decorative/catalogue use only; no safety approval. Official source ↗ |
| Warranty | |||
| Warranty and eligibility | Unknown | Unknown | Unknown |