PUBLIC CATALOGUE • 632 comparison-ready inverter records. Incomplete identities are not shown.
← Choose inverters

Compare inverters.

Exact market specifications side by side, limited to one reviewed comparison category.

Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.

String inverter 3 exact records
Edit selection
Inverter electrical comparison
SpecificationMAX 150KTL3-X2 MVGrowatt New Energy · Global / ROWDeep comparison fields reviewedS1000-G3Fox ESS · Global / ROW official siteDeep comparison fields reviewedS3300-G3Fox ESS · Global / ROW official siteDeep comparison fields reviewed
AC output
Rated AC active power150000 Wmanufacturer datasheet table row as labelled; no design inference Raw/footnote context: 150000W
Official source ↗
1000 Wnominal active AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
3300 Wnominal active AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Maximum AC apparent output165000 VAmanufacturer datasheet table row as labelled; no design inference Raw/footnote context: 165000VA
Official source ↗
1100 VAmaximum apparent AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
4000 VAmaximum apparent AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Connection phases3Task10 exact-model evidence records phase as 'three_phase'; normalized to 3 connection phase(s). Identity/category source is official Growatt evidence; no grid approval inferred. Raw/footnote context: 50/60Hz (45-55Hz/55-65Hz)
Official source ↗
1Official exact-model/family phase identity: single-phase. For North-American split-phase, the literal split-phase descriptor is retained rather than converted to a false phase count. No grid-approval inference.
Official source ↗
1Official exact-model/family phase identity: single-phase. For North-American split-phase, the literal split-phase descriptor is retained rather than converted to a false phase count. No grid-approval inference.
Official source ↗
PV input & tracking
Independent MPPT trackers8manufacturer datasheet table row as labelled; no design inference Raw/footnote context: 8
Official source ↗
1independent MPP trackers; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
1independent MPP trackers; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
MPPT operating window minimum180 Vmanufacturer datasheet table row as labelled; no design inference; lower bound of the manufacturer MPPT operating range. Raw/footnote context: 180-1000V
Official source ↗
50 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
50 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
MPPT operating window maximum1000 Vmanufacturer datasheet table row as labelled; no design inference; upper bound of the manufacturer MPPT operating range. Raw/footnote context: 180-1000V
Official source ↗
480 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
480 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
DC operating voltage minimumUnknownUnknownUnknown
DC operating voltage maximumUnknownUnknownUnknown
Maximum PV input voltage1100 Vmanufacturer datasheet table row as labelled; no design inference Raw/footnote context: 1100V
Official source ↗
500 Vmaximum DC input voltage; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
500 Vmaximum DC input voltage; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Maximum input current per tracker/input45 Amanufacturer datasheet table row as labelled; no design inference Raw/footnote context: 45
Official source ↗
20 Amaximum input current; scope: input; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
20 Amaximum input current; scope: input; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Maximum PV short-circuit current56.5 Amanufacturer datasheet table row as labelled; no design inference Raw/footnote context: 56.5
Official source ↗
26 Amaximum short-circuit current; scope: input; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
26 Amaximum short-circuit current; scope: input; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Efficiency & environment
Maximum conversion efficiency99 %manufacturer datasheet table row as labelled; no design inference Raw/footnote context: 99.0%
Official source ↗
97.2 %maximum conversion efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
97.4 %maximum conversion efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
European efficiency98.5 %manufacturer datasheet table row as labelled; no design inference Raw/footnote context: 98.5%
Official source ↗
96.5 %European efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
96.8 %European efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Operating ambient temperature minimum-30 °Cmanufacturer datasheet table row as labelled; no design inference; lower ambient operating-temperature bound. Raw/footnote context: -30°C ... +60°C
Official source ↗
-25 °Cambient operating range; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
-25 °Cambient operating range; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Operating ambient temperature maximum60 °Cmanufacturer datasheet table row as labelled; no design inference; upper ambient operating-temperature bound. Raw/footnote context: -30°C ... +60°C
Official source ↗
60 °Cambient operating range; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
60 °Cambient operating range; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Enclosure protectionIP66manufacturer datasheet table row as labelled; no design inference Raw/footnote context: IP66
Official source ↗
IP65ingress protection rating; scope: enclosure; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
IP65ingress protection rating; scope: enclosure; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Surge protectionUnknownDC Type II / AC Type II (optional)Manufacturer protection table; optional qualifiers retained where stated. Decorative/catalogue use only; no safety approval.
Official source ↗
DC Type II / AC Type II (optional)Manufacturer protection table; optional qualifiers retained where stated. Decorative/catalogue use only; no safety approval.
Official source ↗
Warranty
Warranty and eligibility5 years standard; 10 years optionalmanufacturer datasheet table row as labelled; no design inference Raw/footnote context: 5 years / 10 years; Yes/Optional
Official source ↗
UnknownUnknown