Compare inverters.
Exact market specifications side by side, limited to one reviewed comparison category.
Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.
String inverter
2 exact records
Edit selection
| Specification | GW100K-HTGoodWe Technologies Co., Ltd. · AustraliaDeep comparison fields reviewed | Tauro ECO 50-3-DFronius International GmbH · Global/International current Help Center; 380/220–400/230 V classDeep comparison fields reviewed |
|---|---|---|
| AC output | ||
| Rated AC active power | 99990 WAustralia nominal output power Official source ↗ | 50000 W Official source ↗ |
| Maximum AC apparent output | 110000 VAMax AC apparent power Official source ↗ | 50000 VA Official source ↗ |
| Connection phases | three-phaseConnection phases stated by exact-family official manufacturer source Official source ↗ | three-phase Official source ↗ |
| PV input & tracking | ||
| Independent MPPT trackers | 10MPP trackers Official source ↗ | 1 Official source ↗ |
| MPPT operating window minimum | 180 VMPPT operating range Official source ↗ | 580 VReviewed MPPT/usable MPP operating window minimum Official source ↗ |
| MPPT operating window maximum | 1000 VMPPT operating range Official source ↗ | 930 VReviewed MPPT/usable MPP operating window maximum Official source ↗ |
| DC operating voltage minimum | Unknown | 580 VPublished DC input/operating range minimum; not relabelled as MPPT Official source ↗ |
| DC operating voltage maximum | Unknown | 1000 VPublished DC input/operating range maximum; not relabelled as MPPT Official source ↗ |
| Maximum PV input voltage | 1100 VMax input voltage Official source ↗ | 1000 V Official source ↗ |
| Maximum input current per tracker/input | 30 AMax input current per MPPT Official source ↗ | 14.5 A Official source ↗ |
| Maximum PV short-circuit current | 45 AMax short circuit current per MPPT Official source ↗ | 20 A Official source ↗ |
| Efficiency & environment | ||
| Maximum conversion efficiency | 98.6 %Max efficiency Official source ↗ | 98.5 % Official source ↗ |
| European efficiency | 98.3 %European efficiency Official source ↗ | Unknown |
| Operating ambient temperature minimum | -30 °COperating temperature Official source ↗ | -40 °COperating ambient temperature minimum Official source ↗ |
| Operating ambient temperature maximum | 60 °COperating temperature Official source ↗ | 65 °COperating ambient temperature maximum Official source ↗ |
| Enclosure protection | IP66Ingress Protection Rating Official source ↗ | IP65 Official source ↗ |
| Surge protection | DC Type II; AC Type IIProtection table Official source ↗ | Unknown |
| Warranty | ||
| Warranty and eligibility | Unknown | Unknown |