PUBLIC CATALOGUE • 632 comparison-ready inverter records. Incomplete identities are not shown.
← Choose inverters

Compare inverters.

Exact market specifications side by side, limited to one reviewed comparison category.

Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.

String inverter 2 exact records
Edit selection
Inverter electrical comparison
SpecificationGW100K-HTGoodWe Technologies Co., Ltd. · AustraliaDeep comparison fields reviewedFronius Primo GEN24 4.6Fronius International GmbH · Europe / ROW current support selectorDeep comparison fields reviewed
AC output
Rated AC active power99990 WAustralia nominal output power
Official source ↗
4600 WAC nominal output (P_ac,r)
Official source ↗
Maximum AC apparent output110000 VAMax AC apparent power
Official source ↗
4600 VAMax. output power (P_ac max); apparent-power unit preserved
Official source ↗
Connection phasesthree-phaseConnection phases stated by exact-family official manufacturer source
Official source ↗
1Task23 QC-approved exact-model/market manufacturer specification.
Official source ↗
PV input & tracking
Independent MPPT trackers10MPP trackers
Official source ↗
2Number of MPP trackers
Official source ↗
MPPT operating window minimum180 VMPPT operating range
Official source ↗
230 VMPP voltage range
Official source ↗
MPPT operating window maximum1000 VMPPT operating range
Official source ↗
530 VMPP voltage range
Official source ↗
DC operating voltage minimumUnknown65 VU_dc min - U_dc max
Official source ↗
DC operating voltage maximumUnknown600 VU_dc min - U_dc max
Official source ↗
Maximum PV input voltage1100 VMax input voltage
Official source ↗
600 VTask23 QC-approved exact-model/market manufacturer specification.
Official source ↗
Maximum input current per tracker/input30 AMax input current per MPPT
Official source ↗
MPPT1 22 / MPPT2 12 AMax. input current (I_dc max), manufacturer two-MPPT topology preserved
Official source ↗
Maximum PV short-circuit current45 AMax short circuit current per MPPT
Official source ↗
MPPT1 41.25 / MPPT2 22 AMax. short circuit current, module array; exact two-MPPT scope
Official source ↗
Efficiency & environment
Maximum conversion efficiency98.6 %Max efficiency
Official source ↗
97.6 %Max. efficiency (PV-grid)
Official source ↗
European efficiency98.3 %European efficiency
Official source ↗
Unknown
Operating ambient temperature minimum-30 °COperating temperature
Official source ↗
-40 °CAmbient temperature range; no extra derating curve inferred
Official source ↗
Operating ambient temperature maximum60 °COperating temperature
Official source ↗
60 °CAmbient temperature range; no extra derating curve inferred
Official source ↗
Enclosure protectionIP66Ingress Protection Rating
Official source ↗
IP66Degree of protection
Official source ↗
Surge protectionDC Type II; AC Type IIProtection table
Official source ↗
Unknown
Warranty
Warranty and eligibilityUnknownUnknown