Compare inverters.
Exact market specifications side by side, limited to one reviewed comparison category.
Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.
String inverter
3 exact records
Edit selection
| Specification | T12(Dual)-G3Fox ESS · Global / ROW — Dual-input material variant from current manualDeep comparison fields reviewed | GW1000-XS-30GoodWe Technologies Co., Ltd. · Global / current international catalogDeep comparison fields reviewed | G10.5-VBFox ESS · Global / ROW — current -VB manual variantDeep comparison fields reviewed |
|---|---|---|---|
| AC output | |||
| Rated AC active power | 12000 Wrated active AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 1000 Wnominal output active power; exact source raw value '1000' W. Converted exactly to website base unit; W and VA not interchanged. Official source ↗ | 10500 Wnominal active AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| Maximum AC apparent output | 13200 VAmaximum apparent AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 1000 VAmaximum AC apparent power; exact source raw value '1000' VA. Converted exactly to website base unit; W and VA not interchanged. Official source ↗ | 11000 VAmaximum apparent AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| Connection phases | 3Official exact-model/family phase identity: three-phase. For North-American split-phase, the literal split-phase descriptor is retained rather than converted to a false phase count. No grid-approval inference. Official source ↗ | 1Connection phase count bound to Task10 exact identity (single-phase); nominal wiring/voltage evidence retained. Official source ↗ | 1Official exact-model/family phase identity: single-phase. For North-American split-phase, the literal split-phase descriptor is retained rather than converted to a false phase count. No grid-approval inference. Official source ↗ |
| PV input & tracking | |||
| Independent MPPT trackers | 2independent MPP trackers; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 1MPP tracker count; exact model/market Task10 evidence reused. Official source ↗ | 2independent MPP trackers; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| MPPT operating window minimum | 140 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 40 VMPPT operating range; endpoint of exact official range [40, 450], not the absolute DC limit. Official source ↗ | 60 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| MPPT operating window maximum | 1000 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 450 VMPPT operating range; endpoint of exact official range [40, 450], not the absolute DC limit. Official source ↗ | 550 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| DC operating voltage minimum | Unknown | Unknown | Unknown |
| DC operating voltage maximum | Unknown | Unknown | Unknown |
| Maximum PV input voltage | 1100 Vmaximum DC input voltage; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 600 Vmaximum PV input voltage; exact model/market Task10 evidence reused. Official source ↗ | 600 Vmaximum DC voltage; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| Maximum input current per tracker/input | 28 / 28 Amaximum input current by tracker; scope: MPPT1/MPPT2; raw source cell retained: 28/28; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 16 ADC input current per MPPT, not total inverter current; per-MPPT/input maximum, not total inverter current. Official source ↗ | 20 / 32 Amaximum input current; scope: input A/input B; raw source cell retained: 20/32; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| Maximum PV short-circuit current | 36.4 / 36.4 Amaximum short-circuit current by tracker; scope: MPPT1/MPPT2; raw source cell retained: 36.4/36.4; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 25 ADC short-circuit current per MPPT; per-MPPT/input maximum, not total inverter current. Official source ↗ | 26 / 42 Amaximum short-circuit current; scope: input A/input B; raw source cell retained: 26/42; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| Efficiency & environment | |||
| Maximum conversion efficiency | 98.6 %maximum conversion efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 97.1 %maximum efficiency; exact model/market Task10 evidence reused. Official source ↗ | 97.8 %maximum conversion efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| European efficiency | 97.8 %European efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 95 %European efficiency; exact model/market Task10 evidence reused. Official source ↗ | 97.4 %European efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| Operating ambient temperature minimum | -25 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | -25 °Coperating temperature range; lower endpoint of exact official range [-25, 60]. Official source ↗ | -25 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| Operating ambient temperature maximum | 60 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 60 °Coperating temperature range; upper endpoint of exact official range [-25, 60]. Official source ↗ | 60 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| Enclosure protection | IP65ingress protection rating; scope: enclosure; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | IP66Official exact-model enclosure ingress-protection rating; no environmental design approval implied. Official source ↗ | IP65ingress protection rating; scope: enclosure; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| Surge protection | PV Type II / AC Type IIManufacturer protection table; optional qualifiers retained where stated. Decorative/catalogue use only; no safety approval. Official source ↗ | DC: Type III (Type II optional); AC: Type III (Type II optional)Official exact-model/family surge-protection rows; optional Type II upgrade retained where stated. Official source ↗ | Unknown |
| Warranty | |||
| Warranty and eligibility | Unknown | Unknown | Unknown |