PUBLIC CATALOGUE • 632 comparison-ready inverter records. Incomplete identities are not shown.
← Choose inverters

Compare inverters.

Exact market specifications side by side, limited to one reviewed comparison category.

Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.

String inverter 3 exact records
Edit selection
Inverter electrical comparison
SpecificationT12(Dual)-G3Fox ESS · Global / ROW — Dual-input material variant from current manualDeep comparison fields reviewedGW1000-XS-30GoodWe Technologies Co., Ltd. · Global / current international catalogDeep comparison fields reviewedG10.5-VBFox ESS · Global / ROW — current -VB manual variantDeep comparison fields reviewed
AC output
Rated AC active power12000 Wrated active AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
1000 Wnominal output active power; exact source raw value '1000' W. Converted exactly to website base unit; W and VA not interchanged.
Official source ↗
10500 Wnominal active AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Maximum AC apparent output13200 VAmaximum apparent AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
1000 VAmaximum AC apparent power; exact source raw value '1000' VA. Converted exactly to website base unit; W and VA not interchanged.
Official source ↗
11000 VAmaximum apparent AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Connection phases3Official exact-model/family phase identity: three-phase. For North-American split-phase, the literal split-phase descriptor is retained rather than converted to a false phase count. No grid-approval inference.
Official source ↗
1Connection phase count bound to Task10 exact identity (single-phase); nominal wiring/voltage evidence retained.
Official source ↗
1Official exact-model/family phase identity: single-phase. For North-American split-phase, the literal split-phase descriptor is retained rather than converted to a false phase count. No grid-approval inference.
Official source ↗
PV input & tracking
Independent MPPT trackers2independent MPP trackers; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
1MPP tracker count; exact model/market Task10 evidence reused.
Official source ↗
2independent MPP trackers; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
MPPT operating window minimum140 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
40 VMPPT operating range; endpoint of exact official range [40, 450], not the absolute DC limit.
Official source ↗
60 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
MPPT operating window maximum1000 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
450 VMPPT operating range; endpoint of exact official range [40, 450], not the absolute DC limit.
Official source ↗
550 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
DC operating voltage minimumUnknownUnknownUnknown
DC operating voltage maximumUnknownUnknownUnknown
Maximum PV input voltage1100 Vmaximum DC input voltage; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
600 Vmaximum PV input voltage; exact model/market Task10 evidence reused.
Official source ↗
600 Vmaximum DC voltage; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Maximum input current per tracker/input28 / 28 Amaximum input current by tracker; scope: MPPT1/MPPT2; raw source cell retained: 28/28; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
16 ADC input current per MPPT, not total inverter current; per-MPPT/input maximum, not total inverter current.
Official source ↗
20 / 32 Amaximum input current; scope: input A/input B; raw source cell retained: 20/32; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Maximum PV short-circuit current36.4 / 36.4 Amaximum short-circuit current by tracker; scope: MPPT1/MPPT2; raw source cell retained: 36.4/36.4; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
25 ADC short-circuit current per MPPT; per-MPPT/input maximum, not total inverter current.
Official source ↗
26 / 42 Amaximum short-circuit current; scope: input A/input B; raw source cell retained: 26/42; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Efficiency & environment
Maximum conversion efficiency98.6 %maximum conversion efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
97.1 %maximum efficiency; exact model/market Task10 evidence reused.
Official source ↗
97.8 %maximum conversion efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
European efficiency97.8 %European efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
95 %European efficiency; exact model/market Task10 evidence reused.
Official source ↗
97.4 %European efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Operating ambient temperature minimum-25 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
-25 °Coperating temperature range; lower endpoint of exact official range [-25, 60].
Official source ↗
-25 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Operating ambient temperature maximum60 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
60 °Coperating temperature range; upper endpoint of exact official range [-25, 60].
Official source ↗
60 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Enclosure protectionIP65ingress protection rating; scope: enclosure; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
IP66Official exact-model enclosure ingress-protection rating; no environmental design approval implied.
Official source ↗
IP65ingress protection rating; scope: enclosure; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Surge protectionPV Type II / AC Type IIManufacturer protection table; optional qualifiers retained where stated. Decorative/catalogue use only; no safety approval.
Official source ↗
DC: Type III (Type II optional); AC: Type III (Type II optional)Official exact-model/family surge-protection rows; optional Type II upgrade retained where stated.
Official source ↗
Unknown
Warranty
Warranty and eligibilityUnknownUnknownUnknown