Compare inverters.
Exact market specifications side by side, limited to one reviewed comparison category.
Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.
String inverter
2 exact records
Edit selection
| Specification | R100-G2Fox ESS · Global / ROW official siteDeep comparison fields reviewed | GW30KLV-MTGoodWe Technologies Co., Ltd. · South America (GoodWe official positioning; exact country/grid certificate not asserted)Deep comparison fields reviewed |
|---|---|---|
| AC output | ||
| Rated AC active power | 100000 Wrated active AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 30000 WOfficial manufacturer technical-table value for the exact model; no compatibility, grid, design or publication approval implied. Official source ↗ |
| Maximum AC apparent output | 110000 VAmaximum apparent AC output for stated market; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 33000 VAOfficial maximum AC apparent output rating for the exact model; W and VA kept separate and model/market footnotes retained. Official source ↗ |
| Connection phases | 3Official exact-model/family phase identity: three-phase. For North-American split-phase, the literal split-phase descriptor is retained rather than converted to a false phase count. No grid-approval inference. Official source ↗ | 3Connection phase count bound to Task10 exact identity (three-phase); nominal wiring/voltage evidence retained. Official source ↗ |
| PV input & tracking | ||
| Independent MPPT trackers | 9Integrated independent MPP tracker count; exact R(G2) model grouping Official source ↗ | 4Official manufacturer technical-table value for the exact model; no compatibility, grid, design or publication approval implied. Official source ↗ |
| MPPT operating window minimum | 200 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 200 VEndpoint of the official MPPT operating voltage range for the exact model; not the absolute DC limit. Official source ↗ |
| MPPT operating window maximum | 1000 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 650 VEndpoint of the official MPPT operating voltage range for the exact model; not the absolute DC limit. Official source ↗ |
| DC operating voltage minimum | Unknown | Unknown |
| DC operating voltage maximum | Unknown | Unknown |
| Maximum PV input voltage | 1100 Vmaximum DC input voltage; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 800 VOfficial manufacturer technical-table value for the exact model; no compatibility, grid, design or publication approval implied. Official source ↗ |
| Maximum input current per tracker/input | 40 Amaximum input current at source scope; scope: source table scope; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 33 AOfficial exact-model row lists per-MPPT sequence [33, 33, 22, 22]; scalar stores the maximum listed per-MPPT value only, not a total. Official source ↗ |
| Maximum PV short-circuit current | 50 Amaximum short-circuit current at source scope; scope: source table scope; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 41.5 AOfficial exact-model row lists per-MPPT sequence [41.5, 41.5, 27.5, 27.5]; scalar stores the maximum listed per-MPPT value only, not a total. Official source ↗ |
| Efficiency & environment | ||
| Maximum conversion efficiency | 98.6 %maximum conversion efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 98.7 %Official manufacturer technical-table value for the exact model; no compatibility, grid, design or publication approval implied. Official source ↗ |
| European efficiency | 98.2 %European efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 98.3 %Official manufacturer technical-table value for the exact model; no compatibility, grid, design or publication approval implied. Official source ↗ |
| Operating ambient temperature minimum | -30 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | -30 °COfficial manufacturer technical-table value for the exact model; no compatibility, grid, design or publication approval implied. Official source ↗ |
| Operating ambient temperature maximum | 60 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 60 °COfficial manufacturer technical-table value for the exact model; no compatibility, grid, design or publication approval implied. Official source ↗ |
| Enclosure protection | IP66ingress protection rating; scope: enclosure; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | IP65Official enclosure ingress-protection rating; catalogue description only, not a safety or suitability approval. Official source ↗ |
| Surge protection | DC Type II / AC Type IIManufacturer protection table; optional qualifiers retained where stated. Decorative/catalogue use only; no safety approval. Official source ↗ | DC: Type II; AC: Type IIOfficial surge-protection configuration for this exact model family; optional enhancements are preserved verbatim where stated. Official source ↗ |
| Warranty | ||
| Warranty and eligibility | Unknown | Unknown |