PUBLIC CATALOGUE • 632 comparison-ready inverter records. Incomplete identities are not shown.
← Choose inverters

Compare inverters.

Exact market specifications side by side, limited to one reviewed comparison category.

Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.

Hybrid / smart energy inverter 2 exact records
Edit selection
Inverter electrical comparison
SpecificationWIT 12K-XHUGrowatt New Energy · Global / ROWDeep comparison fields reviewedGW3600-ES-BR20GoodWe Technologies Co., Ltd. · BrazilDeep comparison fields reviewed
AC output
Rated AC active power12000 WInput/Output AC, AC input/output nominal power (Grid); grid output is second value after slash
Official source ↗
3680 Wnominal/rated active power; exact source raw value '3680' W. Converted exactly to website base unit; W and VA not interchanged.
Official source ↗
Maximum AC apparent output13200 VAInput/Output AC, Max. AC input/output apparent power (Grid); grid output is second value after slash
Official source ↗
3680 VAmaximum apparent power; exact source raw value '3680' VA. Converted exactly to website base unit; W and VA not interchanged.
Official source ↗
Connection phases3Input/Output AC, AC grid connection type 3P3W+PE / 3P4W+PE
Official source ↗
1Connection phase count bound to Task10 exact identity (Single phase); nominal wiring/voltage evidence retained.
Official source ↗
PV input & tracking
Independent MPPT trackers2Input data(PV), No. of MPP trackers
Official source ↗
2count; exact model/market Task10 evidence reused.
Official source ↗
MPPT operating window minimum150 VInput data(PV), MPPT working voltage range
Official source ↗
60 Voperating range; endpoint of exact official range [60, 550], not the absolute DC limit.
Official source ↗
MPPT operating window maximum850 VInput data(PV), MPPT working voltage range
Official source ↗
550 Voperating range; endpoint of exact official range [60, 550], not the absolute DC limit.
Official source ↗
DC operating voltage minimumUnknownUnknown
DC operating voltage maximumUnknownUnknown
Maximum PV input voltage1000 VInput data(PV), Max. input voltage
Official source ↗
600 Vmaximum; exact model/market Task10 evidence reused.
Official source ↗
Maximum input current per tracker/input40 / 20 AInput data(PV), Max. input current per MPP tracker; tracker-specific vector preserved where printed
Official source ↗
16 Aper-MPPT maximum; per-MPPT/input maximum, not total inverter current.
Official source ↗
Maximum PV short-circuit current50 / 25 AInput data(PV), Max. short-circuit current per MPP tracker; tracker-specific vector preserved where printed
Official source ↗
23 Aper-MPPT maximum; per-MPPT/input maximum, not total inverter current.
Official source ↗
Efficiency & environment
Maximum conversion efficiency98.1 %Efficiency, Max. efficiency
Official source ↗
97.6 %maximum efficiency; exact model/market Task10 evidence reused.
Official source ↗
European efficiency97.2 %Efficiency, European efficiency
Official source ↗
96.7 %European efficiency; exact model/market Task10 evidence reused.
Official source ↗
Operating ambient temperature minimum-30 °CGeneral, Operating temperature range minimum
Official source ↗
-25 °Coperating range; lower endpoint of exact official range [-25, 60].
Official source ↗
Operating ambient temperature maximum60 °CGeneral, Operating temperature range maximum; derating >45°C noted in source
Official source ↗
60 °Coperating range; upper endpoint of exact official range [-25, 60].
Official source ↗
Enclosure protectionIP66General, IP degree
Official source ↗
IP65Official enclosure ingress-protection rating; catalogue description only, not a safety or suitability approval.
Official source ↗
Surge protectionUnknownDC: Type II; AC: Type IIOfficial surge-protection configuration for this exact model family; optional enhancements are preserved verbatim where stated.
Official source ↗
Warranty
Warranty and eligibilityUnknownUnknown