Compare inverters.
Exact market specifications side by side, limited to one reviewed comparison category.
Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.
| Specification | SH3.6RSSungrow Power Supply Co., Ltd. · AustraliaDeep comparison fields reviewed | SBSE7.7-US-50SMA Solar Technology AG · United StatesDeep comparison fields reviewed | H3-10.0-SmartFox ESS · Global / ROW — excluding Belgium safety variantDeep comparison fields reviewed |
|---|---|---|---|
| AC output | |||
| Rated AC active power | 3680 WManufacturer rated specification for this exact model and market; no compatibility approval. Source unit W Official source ↗ PDF page 125, SH3.6RS column 2, ac_nominal_w row; retain associated footnotes Revision SH3.0-6.0RS&SH5.0-6.0RS-20-UEN-Ver22-202603 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 7680 Wrated AC active power at 240 V, 60 Hz Source unit W Official source ↗ Datasheet p.2 — AC Rated power (at 240 V, 60 Hz) Revision SBSE-US-DS-en_us-27; current file opened 2026-10-02 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 10000 Wnominal active AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit W Official source ↗ technical table Nominal AC Power Revision V2.0 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Maximum AC apparent output | 3680 VAManufacturer rated specification for this exact model and market; no compatibility approval. Source unit VA Official source ↗ PDF page 125, SH3.6RS column 2, ac_max_va row; retain associated footnotes Revision SH3.0-6.0RS&SH5.0-6.0RS-20-UEN-Ver22-202603 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 7680 VAmaximum apparent AC power Source unit VA Official source ↗ Datasheet p.2 — Max. apparent AC power Revision SBSE-US-DS-en_us-27; current file opened 2026-10-02 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 11000 VAmaximum apparent AC output for stated market; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit VA Official source ↗ technical table Max. Apparent AC Power; Belgium footnote where applicable Revision V2.0 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Connection phases | 1Manufacturer rated specification for this exact model and market; no compatibility approval. Official source ↗ PDF page 126, SH3.6RS column 2, phase row; retain associated footnotes Revision SH3.0-6.0RS&SH5.0-6.0RS-20-UEN-Ver22-202603 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 1Official SMA America product page explicitly identifies this exact SBSE-US family as a 1-phase / single-phase hybrid inverter. Official source ↗ Product page heading: The 1-phase, 2-in-1 hybrid inverter by SMA; exact models 3.8-US / 4.8-US / 5.8-US / 7.7-US / 9.6-US / 11.5-US listed on page. Revision current official product page; accessed 2026-10-02 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 3Official exact-model/family phase identity: three-phase. For North-American split-phase, the literal split-phase descriptor is retained rather than converted to a false phase count. No grid-approval inference. Official source ↗ p.2 AC OUTPUT — Rated Grid Voltage 400/230 V; 380/220 V, 3L/N/PE; exact model column Revision V2.0 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| PV input & tracking | |||
| Independent MPPT trackers | 2Manufacturer rated specification for this exact model and market; no compatibility approval. Official source ↗ PDF page 125, SH3.6RS column 2, mppt_count row; retain associated footnotes Revision SH3.0-6.0RS&SH5.0-6.0RS-20-UEN-Ver22-202603 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 3independent MPPT inputs Official source ↗ Datasheet p.2 — Independent MPPT inputs / inputs per MPPT Revision SBSE-US-DS-en_us-27; current file opened 2026-10-02 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 3independent MPP trackers; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ technical table No. of MPP Trackers Revision V2.0 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| MPPT operating window minimum | 40 VOperating window; full-load window requires the exact user manual. Source unit V Official source ↗ PDF page 125, SH3.6RS column 2, mppt_min_v row; retain associated footnotes Revision SH3.0-6.0RS&SH5.0-6.0RS-20-UEN-Ver22-202603 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 180 Vrated MPP voltage range Source unit V Official source ↗ Datasheet p.2 — Rated MPP voltage range Revision SBSE-US-DS-en_us-27; current file opened 2026-10-02 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 120 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit V Official source ↗ technical table MPPT Voltage Range; canonical min bound from source range Revision V2.0 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| MPPT operating window maximum | 560 VOperating window; full-load window requires the exact user manual. Source unit V Official source ↗ PDF page 125, SH3.6RS column 2, mppt_max_v row; retain associated footnotes Revision SH3.0-6.0RS&SH5.0-6.0RS-20-UEN-Ver22-202603 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 480 Vrated MPP voltage range Source unit V Official source ↗ Datasheet p.2 — Rated MPP voltage range Revision SBSE-US-DS-en_us-27; current file opened 2026-10-02 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 950 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit V Official source ↗ technical table MPPT Voltage Range; canonical max bound from source range Revision V2.0 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| DC operating voltage minimum | Unknown | Unknown | Unknown |
| DC operating voltage maximum | Unknown | Unknown | Unknown |
| Maximum PV input voltage | 600 VManufacturer rated specification for this exact model and market; no compatibility approval. Source unit V Official source ↗ PDF page 125, SH3.6RS column 2, max_dc_v row; retain associated footnotes Revision SH3.0-6.0RS&SH5.0-6.0RS-20-UEN-Ver22-202603 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 600 Vmaximum DC voltage Source unit V Official source ↗ Datasheet p.2 — Max. DC voltage Revision SBSE-US-DS-en_us-27; current file opened 2026-10-02 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 1000 Vmaximum DC voltage; scope: PV input; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit V Official source ↗ technical table Max. DC Voltage; note max operating 950V Revision V2.0 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Maximum input current per tracker/input | 16 A16 A per MPPT; 32 A total (16 A / 16 A). Source unit A Official source ↗ PDF page 125, SH3.6RS column 2, input_current_a row; retain associated footnotes Revision SH3.0-6.0RS&SH5.0-6.0RS-20-UEN-Ver22-202603 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 15 Aper MPPT Source unit A Official source ↗ Datasheet p.2 — Max. usable current input per MPPT Revision SBSE-US-DS-en_us-27; current file opened 2026-10-02 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 20 / 20 / 20 Amaximum current by MPPT; scope: MPPT1/2/3; raw source cell retained: 20/20/20; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit A Official source ↗ technical table Max. MPPT Current Revision V2.0 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Maximum PV short-circuit current | 20 A20 A per MPPT; 40 A total (20 A / 20 A). Source unit A Official source ↗ PDF page 125, SH3.6RS column 2, short_circuit_a row; retain associated footnotes Revision SH3.0-6.0RS&SH5.0-6.0RS-20-UEN-Ver22-202603 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 30 Aper MPPT Source unit A Official source ↗ Datasheet p.2 — Max. short-circuit current input per MPPT Revision SBSE-US-DS-en_us-27; current file opened 2026-10-02 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 25 / 25 / 25 Amaximum short-circuit current by MPPT; scope: MPPT1/2/3; raw source cell retained: 25/25/25; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit A Official source ↗ technical table Max. Short-circuit Current Revision V2.0 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Efficiency & environment | |||
| Maximum conversion efficiency | 97.5 %Manufacturer rated specification for this exact model and market; no compatibility approval. Source unit % Official source ↗ PDF page 126, SH3.6RS column 2, max_efficiency row; retain associated footnotes Revision SH3.0-6.0RS&SH5.0-6.0RS-20-UEN-Ver22-202603 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 98.1 %Current official SMA datasheet max-efficiency row; exact model column/family span visually checked. Source unit % Official source ↗ PDF page 2, Efficiency / Max. efficiency row; 98.1% applies to SBSE3.8/4.8/5.8/7.7 and 98% to SBSE9.6/11.5; type-designation row confirms exact model codes. Revision SBSE-US-DS-en_us-27 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 97.9 %maximum conversion efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit % Official source ↗ technical table Max. Efficiency Revision V2.0 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| European efficiency | 97.1 %Manufacturer rated specification for this exact model and market; no compatibility approval. Source unit % Official source ↗ PDF page 126, SH3.6RS column 2, european_efficiency row; retain associated footnotes Revision SH3.0-6.0RS&SH5.0-6.0RS-20-UEN-Ver22-202603 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | Unknown | 97.2 %European efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit % Official source ↗ technical table European Efficiency Revision V2.0 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Operating ambient temperature minimum | -25 °CManufacturer rated specification for this exact model and market; no compatibility approval. Source unit °C Official source ↗ PDF page 127, SH3.6RS column 2, operating_min_c row; retain associated footnotes Revision SH3.0-6.0RS&SH5.0-6.0RS-20-UEN-Ver22-202603 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | -25 °Cambient operating range; datasheet states with derating Source unit °C Official source ↗ eManual General Data — Operating temperature range Revision current eManual; accessed 2026-10-02 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | -25 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit °C Official source ↗ technical table Operating Temperature; canonical min bound from source range Revision V2.0 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Operating ambient temperature maximum | 60 °CManufacturer rated specification for this exact model and market; no compatibility approval. Source unit °C Official source ↗ PDF page 127, SH3.6RS column 2, operating_max_c row; retain associated footnotes Revision SH3.0-6.0RS&SH5.0-6.0RS-20-UEN-Ver22-202603 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 60 °Cambient operating range; datasheet states with derating Source unit °C Official source ↗ eManual General Data — Operating temperature range Revision current eManual; accessed 2026-10-02 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 60 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit °C Official source ↗ technical table Operating Temperature; canonical max bound from source range Revision V2.0 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Enclosure protection | IP65Manufacturer rated specification for this exact model and market; no compatibility approval. Official source ↗ PDF page 127, SH3.6RS column 2, protection row; retain associated footnotes Revision SH3.0-6.0RS&SH5.0-6.0RS-20-UEN-Ver22-202603 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | IP65electronics ingress protection Official source ↗ eManual General Data — Degree of protection for electronics per IEC 60529 Revision current eManual; accessed 2026-10-02 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | IP65ingress protection rating; scope: enclosure; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ technical table Ingress Protection Revision V2.0 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Surge protection | DC Type II / AC Type IIManufacturer rated specification for this exact model and market; no compatibility approval. Official source ↗ PDF page 126, SH3.6RS column 2, surge_protection row; retain associated footnotes Revision SH3.0-6.0RS&SH5.0-6.0RS-20-UEN-Ver22-202603 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | Unknown | DC Type II / AC Type IIManufacturer protection table; optional qualifiers retained where stated. Decorative/catalogue use only; no safety approval. Official source ↗ p.2 PROTECTION — DC/AC Surge Protection row Revision V2.0 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Warranty | |||
| Warranty and eligibility | Unknown | 10 years standard; extensions stated up to 25 yearsstandard warranty; extension available Maximum extension horizon from same official source. Official source ↗ Product page — Complete reliability Revision current page; accessed 2026-10-02 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | Unknown |