PUBLIC CATALOGUE • 632 comparison-ready inverter records. Incomplete identities are not shown.
← Choose inverters

Compare inverters.

Exact market specifications side by side, limited to one reviewed comparison category.

Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.

String inverter 2 exact records
Edit selection
Inverter electrical comparison
SpecificationMIC 2500TL-X2Growatt New Energy · Global / ROW (Growatt English Worldwide catalog)Deep comparison fields reviewedR80-G2Fox ESS · Global / ROW official siteDeep comparison fields reviewed
AC output
Rated AC active power2500 Wrated/nominal AC active output power Raw/footnote context: 2500W
Official source ↗
80000 Wrated active AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Maximum AC apparent output2500 VAmaximum AC apparent output power Raw/footnote context: 2500VA
Official source ↗
88000 VAmaximum apparent AC output for stated market; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Connection phases1Task10 exact-model evidence records phase as 'Single phase'; normalized to 1 connection phase(s). Identity/category source is official Growatt evidence; no grid approval inferred. Raw/footnote context: Type III
Official source ↗
3Official exact-model/family phase identity: three-phase. For North-American split-phase, the literal split-phase descriptor is retained rather than converted to a false phase count. No grid-approval inference.
Official source ↗
PV input & tracking
Independent MPPT trackers1independent MPP tracker count Raw/footnote context: 1
Official source ↗
9Integrated independent MPP tracker count; exact R(G2) model grouping
Official source ↗
MPPT operating window minimum50 VMPPT operating voltage range; not full-power range unless explicitly stated; lower bound of the manufacturer MPPT operating range. Raw/footnote context: 50-550V
Official source ↗
200 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
MPPT operating window maximum550 VMPPT operating voltage range; not full-power range unless explicitly stated; upper bound of the manufacturer MPPT operating range. Raw/footnote context: 50-550V
Official source ↗
1000 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
DC operating voltage minimumUnknownUnknown
DC operating voltage maximumUnknownUnknown
Maximum PV input voltage550 Vmaximum DC input voltage Raw/footnote context: 550V
Official source ↗
1100 Vmaximum DC input voltage; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Maximum input current per tracker/input16 Amaximum input current at MPP-tracker scope Raw/footnote context: 16A
Official source ↗
40 Amaximum input current at source scope; scope: source table scope; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Maximum PV short-circuit current24 Amaximum short-circuit current at MPP-tracker scope Raw/footnote context: 24A
Official source ↗
50 Amaximum short-circuit current at source scope; scope: source table scope; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Efficiency & environment
Maximum conversion efficiency97.6 %maximum efficiency Raw/footnote context: 97.6%
Official source ↗
98.6 %maximum conversion efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
European efficiency97 %European efficiency Raw/footnote context: 97.0%
Official source ↗
98.2 %European efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Operating ambient temperature minimum-30 °Cambient operating temperature range; lower ambient operating-temperature bound. Raw/footnote context: -30°C...+60°C
Official source ↗
-30 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Operating ambient temperature maximum60 °Cambient operating temperature range; upper ambient operating-temperature bound. Raw/footnote context: -30°C...+60°C
Official source ↗
60 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Enclosure protectionIP66ip rating Raw/footnote context: IP66
Official source ↗
IP66ingress protection rating; scope: enclosure; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Surge protectionDC: Type III; AC: Type IIIManufacturer-published surge-protection rows; AC/DC scope preserved exactly. No safety approval inferred. Raw/footnote context: Type III | Type III
Official source ↗
DC Type II / AC Type IIManufacturer protection table; optional qualifiers retained where stated. Decorative/catalogue use only; no safety approval.
Official source ↗
Warranty
Warranty and eligibility10 years standardstandard/optional warranty duration Raw/footnote context: 10 years
Official source ↗
Unknown