Compare inverters.
Exact market specifications side by side, limited to one reviewed comparison category.
Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.
| Specification | H3-12.0-SmartFox ESS · Global / ROW official siteDeep comparison fields reviewed | GW50K07-ETCGoodWe Technologies Co., Ltd. · GermanyDeep comparison fields reviewed |
|---|---|---|
| AC output | ||
| Rated AC active power | 12000 Wnominal active AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit W Official source ↗ technical table Nominal AC Power Revision V2.0 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 50000 WOn-grid nominal output power; exact source raw value '50 kW' kW. Converted exactly to website base unit; W and VA not interchanged. Source unit W Official source ↗ Technical Data table Revision GoodWe-Single page-20260115-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Maximum AC apparent output | 13200 VAmaximum apparent AC output for stated market; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit VA Official source ↗ technical table Max. Apparent AC Power; Belgium footnote where applicable Revision V2.0 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 55000 VAMax apparent power to utility grid; exact source raw value '55 kVA' kVA. Converted exactly to website base unit; W and VA not interchanged. Source unit VA Official source ↗ Technical Data table Revision GoodWe-Single page-20260115-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Connection phases | 3Official exact-model/family phase identity: three-phase. For North-American split-phase, the literal split-phase descriptor is retained rather than converted to a false phase count. No grid-approval inference. Official source ↗ p.2 AC OUTPUT — Rated Grid Voltage 400/230 V; 380/220 V, 3L/N/PE; exact model column Revision V2.0 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 3Connection phase count bound to Task10 exact identity (three-phase); nominal wiring/voltage evidence retained. Official source ↗ Technical Data table Revision GoodWe-Single page-20260115-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| PV input & tracking | ||
| Independent MPPT trackers | 3independent MPP trackers; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ technical table No. of MPP Trackers Revision V2.0 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 1MPP trackers; exact model/market Task10 evidence reused. Official source ↗ Technical Data table Revision GoodWe-Single page-20260115-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| MPPT operating window minimum | 120 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit V Official source ↗ technical table MPPT Voltage Range; canonical min bound from source range Revision V2.0 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 250 VMPPT operating range; endpoint of exact official range [250, 960], not the absolute DC limit. Source unit V Official source ↗ Technical Data table Revision GoodWe-Single page-20260115-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| MPPT operating window maximum | 950 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit V Official source ↗ technical table MPPT Voltage Range; canonical max bound from source range Revision V2.0 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 960 VMPPT operating range; endpoint of exact official range [250, 960], not the absolute DC limit. Source unit V Official source ↗ Technical Data table Revision GoodWe-Single page-20260115-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| DC operating voltage minimum | Unknown | Unknown |
| DC operating voltage maximum | Unknown | Unknown |
| Maximum PV input voltage | 1000 Vmaximum DC voltage; scope: PV input; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit V Official source ↗ technical table Max. DC Voltage; note max operating 950V Revision V2.0 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 1000 VPV max input voltage; exact model/market Task10 evidence reused. Source unit V Official source ↗ Technical Data table Revision GoodWe-Single page-20260115-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Maximum input current per tracker/input | 20 / 20 / 20 Amaximum current by MPPT; scope: MPPT1/2/3; raw source cell retained: 20/20/20; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit A Official source ↗ technical table Max. MPPT Current Revision V2.0 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 100 AMax input current per MPPT; per-MPPT/input maximum, not total inverter current. Source unit A Official source ↗ Technical Data table Revision GoodWe-Single page-20260115-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Maximum PV short-circuit current | 25 / 25 / 25 Amaximum short-circuit current by MPPT; scope: MPPT1/2/3; raw source cell retained: 25/25/25; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit A Official source ↗ technical table Max. Short-circuit Current Revision V2.0 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 125 AMax short circuit current per MPPT; per-MPPT/input maximum, not total inverter current. Source unit A Official source ↗ Technical Data table Revision GoodWe-Single page-20260115-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Efficiency & environment | ||
| Maximum conversion efficiency | 97.9 %maximum conversion efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit % Official source ↗ technical table Max. Efficiency Revision V2.0 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 97.6 %Max efficiency; exact model/market Task10 evidence reused. Source unit % Official source ↗ Technical Data table Revision GoodWe-Single page-20260115-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| European efficiency | 97.2 %European efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit % Official source ↗ technical table European Efficiency Revision V2.0 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 97.3 %European efficiency; exact model/market Task10 evidence reused. Source unit % Official source ↗ Technical Data table Revision GoodWe-Single page-20260115-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Operating ambient temperature minimum | -25 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit °C Official source ↗ technical table Operating Temperature; canonical min bound from source range Revision V2.0 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | -20 °COperating temp; >45°C derating; lower endpoint of exact official range [-20, 60]. Source unit °C Official source ↗ Technical Data table Revision GoodWe-Single page-20260115-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Operating ambient temperature maximum | 60 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit °C Official source ↗ technical table Operating Temperature; canonical max bound from source range Revision V2.0 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 60 °COperating temp; >45°C derating; upper endpoint of exact official range [-20, 60]. Source unit °C Official source ↗ Technical Data table Revision GoodWe-Single page-20260115-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Enclosure protection | IP65ingress protection rating; scope: enclosure; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ technical table Ingress Protection Revision V2.0 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | IP20Official enclosure ingress-protection rating; catalogue description only, not a safety or suitability approval. Official source ↗ Official technical data / Ingress Protection Rating; exact family/model applicability for GW50K07-ETC. Revision GoodWe-Single page-20260115-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Surge protection | DC Type II / AC Type IIManufacturer protection table; optional qualifiers retained where stated. Decorative/catalogue use only; no safety approval. Official source ↗ p.2 PROTECTION — DC/AC Surge Protection row Revision V2.0 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | DC: Type II (Type I + II optional); AC: Type II (Type I + II optional)Official surge-protection configuration for this exact model family; optional enhancements are preserved verbatim where stated. Official source ↗ Official Protection table / surge-protection rows for family containing exact model GW50K07-ETC. Revision GoodWe-Single page-20260115-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Warranty | ||
| Warranty and eligibility | Unknown | Unknown |