PUBLIC CATALOGUE • 632 comparison-ready inverter records. Incomplete identities are not shown.
← Choose inverters

Compare inverters.

Exact market specifications side by side, limited to one reviewed comparison category.

Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.

Hybrid / smart energy inverter 2 exact records · Differences include rating conditions and scope.
Edit selection
Inverter electrical comparison
SpecificationH3-12.0-SmartFox ESS · Global / ROW official siteDeep comparison fields reviewedMIN 2500TL-XH2Growatt New Energy · Global / ROWDeep comparison fields reviewed
AC output
Rated AC active power12000 Wnominal active AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit W
Official source ↗
technical table Nominal AC Power
Revision V2.0 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

2500 Wrated AC output active power
Source unit W
Official source ↗
PDF p.2, exact model column 'MIN 2500TL-XH2', row 'AC nominal power'
Revision 202607 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Maximum AC apparent output13200 VAmaximum apparent AC output for stated market; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit VA
Official source ↗
technical table Max. Apparent AC Power; Belgium footnote where applicable
Revision V2.0 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

2500 VAmaximum AC apparent power
Source unit VA
Official source ↗
PDF p.2, exact model column 'MIN 2500TL-XH2', row 'Max. AC apparent power'
Revision 202607 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Connection phases3Official exact-model/family phase identity: three-phase. For North-American split-phase, the literal split-phase descriptor is retained rather than converted to a false phase count. No grid-approval inference.
Official source ↗
p.2 AC OUTPUT — Rated Grid Voltage 400/230 V; 380/220 V, 3L/N/PE; exact model column
Revision V2.0 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

single_phaseExact model/market phase classification retained from Task10 source-worker review; no cross-model interpolation.
Official source ↗
Task10 exact-model canonical record: phase=single-phase; official manufacturer family/product evidence retained in provenance_refs.
Revision current page accessed 2026-10-02 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

PV input & tracking
Independent MPPT trackers3independent MPP trackers; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
technical table No. of MPP Trackers
Revision V2.0 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

2independent MPP trackers
Official source ↗
PDF p.2, exact model column 'MIN 2500TL-XH2', row 'No. of MPP trackers'
Revision 202607 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

MPPT operating window minimum120 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit V
Official source ↗
technical table MPPT Voltage Range; canonical min bound from source range
Revision V2.0 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

40 VMPPT operating voltage range
Source unit V
Official source ↗
PDF p.2, exact model column 'MIN 2500TL-XH2', row 'MPP voltage range'
Revision 202607 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

MPPT operating window maximum950 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit V
Official source ↗
technical table MPPT Voltage Range; canonical max bound from source range
Revision V2.0 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

490 VMPPT operating voltage range
Source unit V
Official source ↗
PDF p.2, exact model column 'MIN 2500TL-XH2', row 'MPP voltage range'
Revision 202607 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

DC operating voltage minimumUnknownUnknown
DC operating voltage maximumUnknownUnknown
Maximum PV input voltage1000 Vmaximum DC voltage; scope: PV input; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit V
Official source ↗
technical table Max. DC Voltage; note max operating 950V
Revision V2.0 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

500 VPV maximum input voltage
Source unit V
Official source ↗
PDF p.2, exact model column 'MIN 2500TL-XH2', row 'Max. input voltage'
Revision 202607 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Maximum input current per tracker/input20 / 20 / 20 Amaximum current by MPPT; scope: MPPT1/2/3; raw source cell retained: 20/20/20; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit A
Official source ↗
technical table Max. MPPT Current
Revision V2.0 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

16 Amaximum PV current per MPPT
Source unit A
Official source ↗
PDF p.2, exact model column 'MIN 2500TL-XH2', row 'Max. input current per MPP tracker'
Revision 202607 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Maximum PV short-circuit current25 / 25 / 25 Amaximum short-circuit current by MPPT; scope: MPPT1/2/3; raw source cell retained: 25/25/25; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit A
Official source ↗
technical table Max. Short-circuit Current
Revision V2.0 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

24 Amaximum PV short-circuit current per MPPT
Source unit A
Official source ↗
PDF p.2, exact model column 'MIN 2500TL-XH2', row 'Max. short-circuit current per MPP tracker'
Revision 202607 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Efficiency & environment
Maximum conversion efficiency97.9 %maximum conversion efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit %
Official source ↗
technical table Max. Efficiency
Revision V2.0 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

98.2 %maximum efficiency
Source unit %
Official source ↗
PDF p.2, exact model column 'MIN 2500TL-XH2', row 'Max. efficiency'
Revision 202607 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

European efficiency97.2 %European efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit %
Official source ↗
technical table European Efficiency
Revision V2.0 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Unknown
Operating ambient temperature minimum-25 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit °C
Official source ↗
technical table Operating Temperature; canonical min bound from source range
Revision V2.0 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

-30 °Coperating ambient range
Source unit °C
Official source ↗
PDF p.2, exact model column 'MIN 2500TL-XH2', row 'Operating temperature range'
Revision 202607 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Operating ambient temperature maximum60 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit °C
Official source ↗
technical table Operating Temperature; canonical max bound from source range
Revision V2.0 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

60 °Coperating ambient range
Source unit °C
Official source ↗
PDF p.2, exact model column 'MIN 2500TL-XH2', row 'Operating temperature range'
Revision 202607 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Enclosure protectionIP65ingress protection rating; scope: enclosure; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
technical table Ingress Protection
Revision V2.0 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

IP66enclosure ingress protection
Official source ↗
PDF p.2, exact model column 'MIN 2500TL-XH2', row 'Protection degree'
Revision 202607 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Surge protectionDC Type II / AC Type IIManufacturer protection table; optional qualifiers retained where stated. Decorative/catalogue use only; no safety approval.
Official source ↗
p.2 PROTECTION — DC/AC Surge Protection row
Revision V2.0 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Unknown
Warranty
Warranty and eligibilityUnknown10Manufacturer warranty statement/options as published; eligibility and local terms may vary and are not independently granted by this catalogue review. QC schema normalization: canonical display-field unit is ''; original Task18 unit metadata was 'years'. The value semantics are preserved in the field value/test condition.
Official source ↗
PDF p.2, exact model column 'MIN 2500TL-XH2', row 'Warranty'
Revision 202607 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00